• J. Magn. Reson. · May 2020

    To measure T1 of short T2 species using an inversion recovery prepared three-dimensional ultrashort echo time (3D IR-UTE) method: A phantom study.

    • Zhao Wei, Ya-Jun Ma, Hyungseok Jang, Wenhui Yang, and Jiang Du.
    • Department of Radiology, University of California San Diego, CA, United States; University of Chinese Academy of Sciences, Beijing, China; Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, China. Electronic address: weizhao@mail.iee.ac.cn.
    • J. Magn. Reson. 2020 May 1; 314: 106725.

    PurposeTo demonstrate the feasibility of a new method for measuring T1 of short T2 species based on an adiabatic inversion recovery-prepared three-dimensional ultrashort echo time Cones (3D IR-UTE-Cones) sequence.MethodsT1 values for short T2 species were quantified using 3D IR-UTE-Cones data acquired with different repetition times (TRs) and inversion times (TIs). An inversion efficiency factor Q was introduced into the fitting model to accurately calculate T1 values for short T2 species. Experiments were performed on twelve MnCl2 aqueous solution phantoms with a wide range of T1 values and T2* values on a 3 T clinical MR system to verify the efficacy of the proposed method. For comparison, a variable flip angle UTE (VFA-UTE) sequence, a variable TR UTE (VTR-UTE) sequence, and a conventional 2D IR fast spin echo (IR-FSE) sequence were also used to quantify T1 values of those phantoms. T1 values were compared between all performed sequences.ResultsThe proposed 3D IR-UTE-Cones method provided higher contrast images of short T2 phantoms and measured much shorter T1 values than the VFA-UTE, VTR-UTE and 2D IR-FSE methods. T1 values as short as 2.95 ms could be measured by the 3D IR-UTE-Cones sequence. The 3D IR-UTE-Cones methods with different TRs were applied to different ranges of T1 measurement, and the scan time was significantly decreased by using 5 TIs along the recovery curves to perform fitting with comparable accuracy.ConclusionThe 3D IR-UTE-Cones sequence could accurately measure short T1 values while providing high contrast images of short T2 species.Copyright © 2020 Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…