• J. Heart Lung Transplant. · Apr 2014

    Assessment of myocardial viability and left ventricular function in patients supported by a left ventricular assist device.

    • Deepak K Gupta, Hicham Skali, Jose Rivero, Patricia Campbell, Leslie Griffin, Colleen Smith, Courtney Foster, Brian Claggett, Robert J Glynn, Gregory Couper, Michael M Givertz, Mandeep R Mehra, Marcelo Di ... more Carli, Scott D Solomon, and Marc A Pfeffer. less
    • Cardiovascular Division, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts.
    • J. Heart Lung Transplant. 2014 Apr 1; 33 (4): 372-81.

    BackgroundChronically supported left ventricular assist device (LVAD) patients may be candidates for novel therapies aimed at promoting reverse remodeling and myocardial recovery. However, the effect of hemodynamic unloading with a LVAD on myocardial viability and LV function in chronically supported LVAD patients has not been fully characterized. We aimed to develop a non-invasive imaging protocol to serially quantify native cardiac structure, function, and myocardial viability while at reduced LVAD support.MethodsClinically stable (n = 18) ambulatory patients (83% men, median age, 61 years) supported by a HeartMate II (Thoratec, Pleasanton, CA) LVAD (median durations of heart failure 4.6 years and LVAD support 7 months) were evaluated by echocardiography and technetium-99m ((99m)Tc)-sestamibi single photon emission computed tomography (SPECT) imaging at baseline and after an interval of 2 to 3 months. Echocardiographic measures of LV size and function, including speckle tracking-derived circumferential strain, were compared between ambulatory and reduced LVAD support at baseline and between baseline and follow-up at reduced LVAD support. The extent of myocardial viability by SPECT was compared between baseline and follow-up at reduced LVAD support.ResultsWith reduction in LVAD speeds (6,600 rpm; interquartile range: 6,200, 7,400 rpm), LV size increased, LV systolic function remained stable, and filling pressures nominally worsened. After a median 2.1 months, cardiac structure, function, and the extent of viable myocardium, globally and regionally, was unchanged on repeat imaging while at reduced LVAD speed.ConclusionsIn clinically stable chronically supported LVAD patients, intrinsic cardiac structure, function, and myocardial viability did not significantly change over the pre-specified time frame. Echocardiographic circumferential strain and (99m)Tc-sestamibi SPECT myocardial viability imaging may provide useful non-invasive end points for the assessment of cardiac structure and function, particularly for phase II studies of novel therapies aimed at promoting reverse remodeling and myocardial recovery in LVAD patients.Copyright © 2014 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation  

      Add institutional full text...

    Notes

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.