• Spine · Mar 2012

    Comparative Study

    Comparison of 4 airway devices on cervical spine alignment in a cadaver model with global ligamentous instability at C5-C6.

    • Mark L Prasarn, Bryan Conrad, Paul T Rubery, Adam Wendling, Tolga Aydog, MaryBeth Horodyski, and Glenn R Rechtine.
    • University of Rochester/Strong Memorial Hospital, Rochester, NY, USA. mark_prasarn@urmc.rochester.edu
    • Spine. 2012 Mar 15;37(6):476-81.

    Study DesignHuman cadaveric study using various intubation devices in a cervical spine instability model.ObjectiveWe sought to evaluate various intubation techniques and determine which device results in the least cervical motion in the setting of a global ligamentous instability model.Summary Of Background DataMany patients presenting with a cervical spine injury have other injuries that may require rapid airway management with endotracheal intubation. Secondary neurologic injuries may occur in these patients because of further displacement at the level of injury, vascular insult, or systemic decrease in oxygen delivery. The most appropriate technique for achieving endotracheal intubation in the patient with a cervical spine injury remains controversial.MethodsA global ligamentous instability at the C5-C6 vertebral level was created in lightly embalmed cadavers. An electromagnetic motion analysis device (Liberty; Polhemus, Colchester, VT) was used to assess the amount of angular and linear translation in 3 planes during intubation trials with each of 4 devices (Airtraq laryngoscope, lighted stylet, intubating LMA, and Macintosh laryngoscope). The angular motions measured were flexion-extension, axial rotation, and lateral bending. Linear translation was measured in the medial-lateral (ML), axial, and anteroposterior planes. Intubation was performed by either an emergency medical technician or by a board-certified attending anesthesiologist. Both time to intubate as well as failure to intubate (after 3 attempts) were recorded.ResultsThere was no significant difference shown with regards to time to successfully intubate using the various devices. It was shown that the highest failure-to-intubate rate occurred with use of the intubating LMA (ILMA) (23%) versus 0% for the others. In flexion/extension, we were able to demonstrate that the Lightwand (P = 0.005) and Airtraq (P = 0.019) resulted in significantly less angular motion than the Macintosh blade. In anterior/posterior translation, the Lightwand (P = 0.005), Airtraq (P = 0.024), and ILMA (P = 0.021) all caused significantly less linear motion than the Macintosh blade. In axial rotation, the Lightwand (P = 0.017) and Airtraq (P = 0.022) resulted in significantly less angular motion than the Macintosh blade. In axial translation (P = 0.037) and lateral bending (P = 0.003), the Lightwand caused significantly less motion than the Macintosh blade.ConclusionIn a cadaver model of C5-C6 instability, the greatest amount of motion was caused by the most commonly used intubation device, the Macintosh blade. Intubation with the Lightwand resulted in significantly less motion in all tested parameters (other than ML translation) as compared with the Macintosh blade. It should also be noted that the Airtraq caused less motion than the Macintoshblade in 3 of the 6 tested planes. There were no significant differences in failure rate or the amount of time it took to successfully intubate in comparing these techniques. We therefore recommend the use of the Lightwand, followed by the Airtraq, in the setting of a presumed unstable cervical spine injury over the Macintosh laryngoscope.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…