• Acta Anaesthesiol Scand · Oct 2006

    Clinical Trial

    Cardiac output--pulse contour analysis vs. pulmonary artery thermodilution.

    • M Ostergaard, J Nielsen, J P Rasmussen, and P G Berthelsen.
    • Department of Anaesthesiology, Copenhagen University Hospital, Gentofte, Hellerup, Denmark. morten.ostergaard@dadlnet.dk
    • Acta Anaesthesiol Scand. 2006 Oct 1;50(9):1044-9.

    BackgroundThe aims of this study were to determine the agreement between pulmonary artery thermodilution (PA-TD), transpulmonary thermodilution (TP-TD) and the pulse contour method, and to test the ability of the pulse contour method to track changes in cardiac output.MethodsCardiac output was determined twice before cardiac surgery with both PA-TD and TP-TD. The precision (two standard deviations of the difference between repeated measurements) and agreement of the two methods were calculated. Post-operatively, cardiac output was determined with the PA-TD and pulse contour methods, and the bias and limits of agreement were again calculated. Finally, in patients with heart rates below 60 beats/min or a cardiac index of less than 2.5 l/min/m2, atrial pacing was started and the haemodynamic consequences were monitored with the PA-TD and pulse contour methods.ResultsTwenty-five patients were included. The precisions of PA-TD and TP-TD were 0.41 l/min [95% confidence interval (CI), +/- 0.07] and 0.48 l/min (95% CI, +/- 0.08), respectively. The bias and limits of agreement between PA-TD and TP-TD were - 0.46 l/min (95% CI, +/- 0.11) and +/- 1.10 l/min (95% CI, +/- 0.19), respectively. Post-operatively, the bias and limits of agreement between the PA-TD and pulse contour methods were 0.07 l/min and +/- 2.20 l/min, respectively. The changes in cardiac output with atrial pacing were in the same direction and of the same magnitude in 15 of the 16 patients.ConclusionThe precision of cardiac output measurements with PA-TD and TP-TD was very similar. The transpulmonary method, however, overestimated the cardiac output by 0.46 l/min. Post-operatively, cardiac output measurements with the PA-TD and pulse contour methods did not agree, but the pulse contour method reliably tracked pacing-induced changes in cardiac output.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?

    User can't be blank.

    Content can't be blank.

    Content is too short (minimum is 15 characters).

    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.