• Eur J Anaesthesiol · Feb 2008

    Comparative Study

    Transoesophageal echocardiography accurately detects cardiac output variation: a prospective comparison with thermodilution in cardiac surgery.

    • V Parra, G Fita, I Rovira, P Matute, C Gomar, and C Paré.
    • Universidad de Chile, Hospital Clínico y Facultad de Medicina, Anestesiología, Santiago, Chile. vparra@med.uchile.cl
    • Eur J Anaesthesiol. 2008 Feb 1;25(2):135-43.

    Background And ObjectiveIntraoperative Doppler ultrasound can be used to measure cardiac output by transoesophageal echocardiography. Recently, its reliability, when compared to the thermodilution technique, has been questioned. The purpose of this study was to compare intraoperative changes in cardiac output measured by echo-Doppler and by thermodilution in cardiac surgery. We also assessed the agreement between the techniques.MethodsFifty cardiac surgical patients (38 male, 12 female, mean age of 63.4 +/- 14.3 yr) were prospectively included after approval by the Ethics Committee of the Institution. Cardiac output was assessed by thermodilution, with 10 mL saline at 12 degrees C, and simultaneously and blindly by echo-Doppler in deep transgastric view with pulsed wave Doppler at the level of the left ventricular outflow tract. Matched thermodilution cardiac output and echo-Doppler cardiac output measurements were taken three times at the end of expiration, both pre- and post-cardiopulmonary bypass.ResultsEcho-Doppler measurements were obtained in 44 patients (88%). In three patients, Doppler recordings could not be obtained adequately, and three developed left ventricular outflow tract obstruction after bypass. Bland-Altman analysis revealed a bias of 0.015 L min(-1), with narrow limits of agreement (-1.21 to 1.22 L min(-1)) and 29.1% error. Echo-Doppler was accurate (92% sensitivity and 71% specificity, P = 0.008 by receiver operating characteristic curves) for detecting more than 10% of change in thermodilution cardiac output. There were no complications related to the study.ConclusionsThe agreement between cardiac output by echo-Doppler and by thermodilution is clinically acceptable and transoesophageal echocardiography is a reliable tool to assess significant cardiac output changes in a population of selected patients.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…