-
Randomized Controlled Trial Comparative Study Clinical Trial
Stability of the LMA-ProSeal and standard laryngeal mask airway in different head and neck positions: a randomized crossover study.
- J Brimacombe and C Keller.
- University of Queensland James Cook University, Department of Anaesthesia and Intensive Care, Cairns Base Hospital, The Esplanade, Australia. jbrimacombe@austarnet.com.au
- Eur J Anaesthesiol. 2003 Jan 1;20(1):65-9.
Background And ObjectiveThe LMA-ProSeal laryngeal mask airway is a new laryngeal mask airway with a modified cuff and drainage tube. We compared oropharyngeal leak pressure, intracuff pressure and anatomical position (assessed fibreoptically) for the Size 5 LMA-ProSeal laryngeal mask airway and the classic laryngeal mask airway in different head-neck positions and using different intracuff inflation volumes.MethodsThirty paralysed anaesthetized adult male patients were studied. The LMA-ProSeal laryngeal mask airway and the classic laryngeal mask airway were inserted into each patient in random order. The oropharyngeal leak pressure, intracuff pressure, and anatomical position of the airway tube and drainage tube (LMA-ProSeal laryngeal mask airway only) were documented in four head and neck positions (neutral first, then flexion, extension and rotation in random order), and at 0-40 mL cuff volumes in the neutral position in 10 mL increments.ResultsCompared with the neutral position, the oropharyngeal leak pressure for both the LMA-ProSeal laryngeal mask airway and the classic laryngeal mask airway was higher in flexion and rotation (all P < or = 0.02), but lower in extension (all P < or = 0.01). Changes in head-neck position did not alter the anatomical position of the airway tube or the drainage tube. The oropharyngeal leak pressure was always higher for the LMA-ProSeal laryngeal mask airway (all P < or = 0.005) and anatomical position better for the classic laryngeal mask airway (all P < or = 0.04).ConclusionsThe anatomical position of the LMA-ProSeal and the classic laryngeal mask airway is stable in different head-neck positions, but head-neck flexion and rotation are associated with an increase, and head-neck extension a decrease, in oropharyngeal leak pressure and intracuff pressure. The Size 5 LMA-ProSeal laryngeal mask airway is capable of forming a more effective seal than the Size 5 classic laryngeal mask airway in males.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.