• JACC Cardiovasc Imaging · Jul 2012

    Comparative Study

    Direct measurement of multiple vena contracta areas for assessing the severity of mitral regurgitation using 3D TEE.

    • Eiichi Hyodo, Shinichi Iwata, Aylin Tugcu, Kotaro Arai, Kenei Shimada, Takashi Muro, Junichi Yoshikawa, Minoru Yoshiyama, Linda D Gillam, Rebecca T Hahn, Marco R Di Tullio, and Shunichi Homma.
    • Cardiology Department, Columbia University Medical Center, New York, New York 10032, USA. ehyodo47@gmail.com
    • JACC Cardiovasc Imaging. 2012 Jul 1;5(7):669-76.

    ObjectivesThe aim of this study was to determine whether direct measurement of multiple-jet vena contracta (VC) areas by real-time 3-dimensional (3D) transesophageal echocardiography is an accurate method for measuring the severity of mitral regurgitation (MR) in patients with multiple MR jets.BackgroundBecause of the conflicting requirements of Doppler and imaging physics, measuring VC using 2-dimensional (2D) echocardiography is a difficult procedure for assessing MR severity. A real-time 3D echocardiographic measurement of the VC area has been validated in a single jet of MR, but the applicability of this method for multiple jets is unknown.MethodsTwo-dimensional and 3D transesophageal echocardiography was performed in 60 patients with multiple functional MR jets. MR severity was assessed quantitatively using the effective regurgitant orifice area derived from 3D left ventricular volume and thermodilution data (EROAstd). Manual tracings of multiple 3D VC areas in a cross-sectional plane through the VC were obtained, and the sum of the areas was compared using EROAstd. Similarly, 2D measurement of VC diameter was obtained from a 2D transesophageal echocardiographic view to optimize the largest legion size in each jet. All VC diameters were summed and compared with EROAstd.ResultsThe correlation of the sum of the multiple 3D VC areas with EROAstd (r = 0.90, p < 0.01) was higher than that of the sum of the multiple 2D VC diameters (r = 0.56, p < 0.01), particularly with MR degrees greater than mild (r = 0.80, p < 0.01 vs. r = 0.05, p = 0.81) and in cases of 3 or more regurgitant jets (r = 0.91, p < 0.01 vs. r = 0.46, p = 0.05).ConclusionsDirect measurement of multiple VC areas using 3D transesophageal echocardiography allows for assessing MR severity in patients with multiple jets, particularly for MR degrees greater than mild and in cases of more than 2 jets, for which geometric assumptions may be challenging.Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…