• European heart journal · Aug 2000

    Multicenter Study Comparative Study Clinical Trial

    Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable?

    • N G Bellenger, M I Burgess, S G Ray, A Lahiri, A J Coats, J G Cleland, and D J Pennell.
    • Cardiovascular MR Unit, Royal Brompton Hospital, National Heart and Lung Institute, Imperial College, London, UK.
    • Eur. Heart J. 2000 Aug 1;21(16):1387-96.

    AimsTo prospectively compare the agreement of left ventricular volumes and ejection fraction by M-mode echocardiography (echo), 2D echo, radionuclide ventriculography and cardiovascular magnetic resonance performed in patients with chronic stable heart failure. It is important to know whether the results of each technique are interchangable, and thereby how the results of large studies in heart failure utilizing one technique can be applied using another. Some studies have compared cardiovascular magnetic resonance with echo or radionuclude ventriculography but few contain patients with heart failure and none have compared these techniques with the current fast breath-hold acquisition cardiovascular magnetic resonance.Methods And ResultsFifty two patients with chronic stable heart failure taking part in the CHRISTMAS Study, underwent M-mode echo, 2D echo, radionuclude ventriculography and cardiovascular magnetic resonance within 4 weeks. The scans were analysed independently in blinded fashion by a single investigator at three core laboratories. Of the echocardiograms, 86% had sufficient image quality to obtain left ventricular ejection fraction by M-mode method, but only 69% by 2D Simpson's biplane analysis. All 52 patients tolerated the radionuclude ventriculography and cardiovascular magnetic resonance, and all these scans were analysable. The mean left ventricular ejection fraction by M-mode cube method was 39+/-16% and 29+/-15% by Teichholz M-mode method. The mean left ventricular ejection fraction by 2D echo Simpson's biplane was 31+/-10%, by radionuclude ventriculography was 24+/-9% and by cardiovascular magnetic resonance was 30+/-11. All the mean left ventricular ejection fractions by each technique were significantly different from all other techniques (P<0.001), except for cardiovascular magnetic resonance ejection fraction and 2D echo ejection fraction by Simpson's rule (P=0.23). The Bland-Altman limits of agreement encompassing four standard deviations was widest for both cardiovascular magnetic resonance vs cube M-mode echo and cardiovascular magnetic resonance vs Teichholz M-mode echo at 66% each, and was 58% for radionuclude ventriculography vs cube M-mode echo, 44% for cardiovascular magnetic resonance vs Simpson's 2D echo, 39% for radionuclide ventriculography vs Simpson's 2D echo, and smallest at 31% for cardiovascular magnetic resonance-radionuclide ventriculography. Similarly, the end-diastolic volume and end-systolic volume by 2D echo and cardiovascular magnetic resonance revealed wide limits of agreement (52 ml to 216 ml and 11 ml to 188 ml, respectively).ConclusionThese results suggest that ejection fraction measurements by various techniques are not interchangeable. The conclusions and recommendations of research studies in heart failure should therefore be interpreted in the context of locally available techniques. In addition, there are very wide variances in volumes and ejection fraction between techniques, which are most marked in comparisons using echocardiography. This suggests that cardiovascular magnetic resonance is the preferred technique for volume and ejection fraction estimation in heart failure patients, because of its 3D approach for non-symmetric ventricles and superior image quality.Copyright 2000 The European Society of Cardiology.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.