• Critical care medicine · Jul 2002

    Randomized Controlled Trial Clinical Trial

    Automatic tube compensation in patients after cardiac surgery: effects on oxygen consumption and breathing pattern.

    • Wolfgang Oczenski, Anton Kepka, Herbert Krenn, Robert D Fitzgerald, Sylvia Schwarz, and Christoph Hörmann.
    • Department of Anesthesia and Intensive Care and the Ludwig Boltzmann Institute for Economics of Medicine in Anesthesia and Intensive Care, Vienna City Hospital-Lainz, Vienna, Austria. ocw@ana.khl.magwien.gv.at
    • Crit. Care Med. 2002 Jul 1;30(7):1467-71.

    ObjectiveTo evaluate patients without prior pulmonary disease after cardiac surgery and to determine whether resistive unloading by automatic tube compensation, pressure support ventilation, and continuous positive airway pressure has different effects on oxygen consumption, breathing pattern, gas exchange, and hemodynamics.DesignProspective, randomized, controlled study.SettingTertiary care, postoperative intensive care unit.PatientsTwenty-one patients scheduled for open heart coronary artery bypass graft surgery.InterventionsEach patient was ventilated with all three modes in random order.Measurements And Main ResultsPatients were ventilated in three modes, each applied for 30 mins according to computer-generated randomization: pressure support ventilation with 5 cm H2O, continuous positive airway pressure, and automatic tube compensation. Oxygen consumption was calculated by means of indirect calorimetry. The hypnotic state of the patients was monitored by Bispectral Index. For hemodynamic measurements, a fiberoptic pulmonary artery catheter was inserted. The main finding of our study was that oxygen consumption and breathing pattern (tidal volume and respiratory rate) did not differ significantly during automatic tube compensation and pressure support ventilation compared with continuous positive airway pressure (oxygen consumption, 170 +/- 29 vs. 170 +/- 26 vs. 174 +/- 29 mL.min.m, respectively; tidal volume, 466 +/- 132 vs. 484 +/- 125 vs. 470 +/- 119 mL, respectively; respiratory rate, 16 +/- 4 vs. 15 +/- 4 vs. 16 +/- 4 breaths/min, respectively). Automatic tube compensation and pressure support ventilation had no clinical effects on gas exchange and hemodynamic variables compared with continuous positive airway pressure. None of the variables differed significantly during the three ventilatory settings.ConclusionIn postoperative tracheally intubated patients with normal ventilatory demand, automatic tube compensation and pressure support ventilation with 5 cm H2O lead to identical oxygen consumption, breathing patterns, gas exchange, and hemodynamics. We, therefore, suggest that this group of patients does not need any additional positive pressure support from the ventilator to overcome the additional work of breathing imposed by the endotracheal tube during the weaning phase from mechanical ventilation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…