• Anesth Essays Res · Sep 2015

    Comparison of hemodynamic responses to intubation: Flexible fiberoptic bronchoscope versus McCoy laryngoscope in presence of rigid cervical collar simulating cervical immobilization for traumatic cervical spine.

    • Nitesh Gill, Shobha Purohit, Poonam Kalra, Tarun Lall, and Avneesh Khare.
    • Department of Anaesthesiology, S.M.S. Medical College, Jaipur, Rajasthan, India.
    • Anesth Essays Res. 2015 Sep 1;9(3):337-42.

    BackgroundIntubation is known to cause an exaggerated hemodynamic response in the form of tachycardia, hypertension, and dysrhythmias. In cervical spine instability, intubation has to be performed using cervical immobilization to prevent exacerbation of spinal cord injuries. Application of rigid cervical collar may reduce cervical spine movements, but it hinders tracheal intubation with a standard laryngoscope. The aim of this study was to compare the hemodynamic responses to fiberoptic bronchoscope (FOB) and McCoy laryngoscope in patients undergoing elective surgery under general anesthesia with rigid cervical collar simulating cervical spine immobilization in the situation of cervical trauma.MethodsThirty-two patients in the age range 20-50 years, of American Society of Anaesthesiologist I-II, and of either sex undergoing elective surgery under general anesthesia were randomly allocated into each group. There were two groups according to the technique used for intubation: Group A (flexible FOB) and Group B (McCoy laryngoscope). Systolic blood pressure, diastolic blood pressure, mean arterial blood pressure and heart rate (HR) were recorded at baseline, intraoperatively, immediately before and after induction, and immediately after intubation. Thereafter, every min for next 5 min.Statistical AnalysisIntergroup comparison of categorical data was done by Chi-square test. P < 0.05 was considered statistically significant. Intergroup comparison of quantitative data was done by the parametric test (unpaired t-test), and probability was considered to be significant if <0.05.ResultsDue to intubation response, HR and blood pressure increased significantly (P < 0.05) above preoperative values in McCoy group as compared to the fiberoptic group.ConclusionWe suggest that the flexible FOB is an effective and better method of intubation in a situation like traumatic cervical spine injury and provides stable hemodynamics.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…