-
Randomized Controlled Trial
Miniaturized cardiopulmonary bypass in coronary artery bypass surgery: marginal impact on inflammation and coagulation but loss of safety margins.
- Georg Nollert, Ina Schwabenland, Deniz Maktav, Felix Kur, Frank Christ, Peter Fraunberger, Bruno Reichart, and Calin Vicol.
- Clinic of Cardiac Surgery, University of Munich, Munich, Germany. georg.nollert@med.uni-muenchen.de
- Ann. Thorac. Surg. 2005 Dec 1; 80 (6): 2326-32.
PurposeInflammation and coagulation disturbances are common consequences of cardiopulmonary bypass (CPB). Recently, miniaturized closed CPB circuits without cardiotomy suction and venous reservoir have been proposed to reduce complication rates. We compared outcomes with conventional (CCPB) and miniaturized cardiopulmonary bypass (MCPB) after coronary artery bypass operations (CABG) with respect to inflammation and coagulation.DescriptionThirty patients (23% female; aged 67.9 +/- 9.0 years) were prospectively randomly assigned to undergo isolated CABG with CCPB or MCPB. Conventional CPB had a pump prime of 1, 600 mL. Miniaturized CPB consisted of a centrifugal pump, arterial filter, heparinized tubing, and oxygenator with a priming volume of 800 mL. Shed blood was removed by a cell-saving device and reinfused. Measurements included interleukin (IL)-2 receptor, IL-6, IL-10, tumor necrosis factor receptor 55 and 75, C reactive protein, leukocyte differentiation, d-dimers, fibrinogen, and thrombocytes at six time points.EvaluationIn both groups no major complication occurred. However, two dangerous air leaks occurred in the closed MCPB circuit, demonstrating the narrow safety margins. Operative handling was also more difficult owing to limitations in venting and fluid management. International normalized ratio (p = 0.03) and antithrombin III (p = 0.04) levels were elevated during CPB in the CCPB group, most likely owing to differences of the intraoperative anticoagulation management. Repeated measures analysis revealed that not a single parameter of inflammation or clinical outcome showed significant differences among groups.ConclusionsUse of a MCPB affected inflammation and coagulation variables only marginally and did not lead to clinical relevant changes as assessed by blood loss, need for blood products, and intensive care unit and clinical stays. However, safety margins for volume loss, air emboli, and weaning from CPB decrease, because of the closed MCPB circuit.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:

- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.