European journal of nuclear medicine and molecular imaging
-
Eur. J. Nucl. Med. Mol. Imaging · Jun 2004
Performance evaluation of the new whole-body PET/CT scanner: Discovery ST.
Characterisation of the physical performance of the new integrated PET/CT system Discovery ST (GE Medical Systems) has been performed following the NEMA NU 2-1994 (N-94) and the NEMA NU 2-2001 (N-01) standards in both 2D and 3D acquisition configuration. The Discovery ST combines a four or eight multi-slice helical CT scanner with a PET tomograph which consists of 10,080 BGO crystals arranged in 24 rings. The crystal dimensions are 6.3 x 6.3 x 30 mm(3) and they are organised in blocks of 6 x 6 crystals, coupled to a single photomultiplier tube with four anodes. ⋯ Using the NEMA N-94 standard, the main results were: (1) the average (radial and tangential) transverse spatial resolution (FWHM) at 1, 10 and 20 cm off axis was 6.28 mm, 7.09 mm and 7.45 mm in 2D, and 6.68 mm, 7.72 mm and 8.13 mm in 3D; (2) the sensitivity for true events was 8,567 cps/kBq/cc in 2D and 36,649 cps/kBq/cc in 3D; (3) the scatter fraction was 15% in 2D and 30% in 3D; (4) the peak true events rate, the true events rate at 50% of the system dead-time and the true events rate when equal to the random events rate were 750 kcps at 189.81 kBq/cc, 744 kcps at 186.48 kBq/cc and 686 kcps at 150.59 kBq/cc, respectively, in 2D, and 922 kcps at 44.03 kBq/cc, 834 kcps at 53.28 kBq/cc and 921 kcps at 44.03 kBq/cc in 3D; (5) the noise equivalent count (NEC) peak rate was 270 kcps at 34.38 kBq/cc in 3D, with random coincidences estimated by delayed events. Using the NEMA N-01 standards the main results were: (1) the average transverse and axial spatial resolution (FWHM) at 1 cm and 10 cm off axis was 6.28 (4.56) mm and 6.88 (6.11) mm in 2D, and 6.29 (5.68) mm and 6.82 (6.05) mm in 3D; (2) the average sensitivity for the two radial positions (r=0 cm and r=10 cm) was 1.93 cps/kBq in 2D and 9.12 cps/kBq in 3D; (3) the scatter fraction was 19% in 2D and 45% in 3D; (4) the NEC peak rate was 54 kcps at 46.99 kBq/cc in 2D and 45.5 kcps at 10.84 kBq/cc in 3D, when random coincidences were estimated by using k=2 in the NEC formula, while the NEC peak rate was 81 kcps at 64.43 kBq/cc and 66 kcps at 14.86 kBq/cc in 2D and 3D, respectively, when random coincidences were estimated by using k=1 in the NEC formula. The new integrated PET-CT system Discovery ST has good overall performances in both 2D and 3D, with in particular a high sensitivity and a very good 3D NEC response.
-
Eur. J. Nucl. Med. Mol. Imaging · May 2004
Comparative Study Clinical Trial Controlled Clinical TrialEstimating the input function non-invasively for FDG-PET quantification with multiple linear regression analysis: simulation and verification with in vivo data.
A novel statistical method, namely Regression-Estimated Input Function (REIF), is proposed in this study for the purpose of non-invasive estimation of the input function for fluorine-18 2-fluoro-2-deoxy- d-glucose positron emission tomography (FDG-PET) quantitative analysis. We collected 44 patients who had undergone a blood sampling procedure during their FDG-PET scans. First, we generated tissue time-activity curves of the grey matter and the whole brain with a segmentation technique for every subject. ⋯ Regression analysis of the CMRGlc values derived from the real and estimated input functions revealed a high correlation (r=0.91). No significant difference was found between the real CMRGlc and that derived from our regression-estimated input function (Student's t test, P>0.05). The proposed REIF method demonstrated good abilities for input function and CMRGlc estimation, and represents a reliable replacement for the blood sampling procedures in FDG-PET quantification.
-
Eur. J. Nucl. Med. Mol. Imaging · May 2004
Clinical TrialSubareolar injection of technetium-99m nanocolloid yields reliable data on the axillary lymph node tumour status in breast cancer patients with previous manipulations on the primary tumour: a prospective study of 117 patients.
According to recently published guidelines, histological clarification by interventional techniques should be undertaken before planning the surgical management of patients with breast carcinoma. In patients with previous manipulations on the primary tumour, peritumoural injection in the context of preoperative scintigraphic detection of the sentinel lymph nodes is not possible. The aim of this prospective study was to clarify whether subareolar injection of nanocolloid can yield reliable data on the axillary lymph node tumour status in breast cancer patients with previous manipulations on the primary tumour. ⋯ In six of them, non-sentinel lymph nodes also showed tumour involvement. In the remaining 91 patients, lymph node metastases could be found neither in sentinel lymph nodes nor in non-sentinel lymph nodes. In conclusion, subareolar nanocolloid injection can yield reliable information on the axillary lymph node tumour status in patients with previous manipulations on the primary tumour in the breast.
-
Eur. J. Nucl. Med. Mol. Imaging · May 2004
Comparative StudyDetection of focal hypoxic-ischemic injury and neuronal stress in a rodent model of unilateral MCA occlusion/reperfusion using radiolabeled annexin V.
In this study we wished to determine whether technetium-99m annexin V, an in vivo marker of cellular injury and death, could be used to noninvasively monitor neuronal injury following focal middle cerebral artery (MCA) occlusion/reperfusion injury. Sixteen adult male Sprague-Dawley rats (along with four controls) underwent left (unilateral) MCA intraluminal beaded thread occlusion for 2 h followed by reperfusion. One hour following tail vein injection of 5-10 mCi of (99m)Tc-annexin V, animals underwent either single-photon emission computerized tomography (SPECT) or autoradiography followed by immunohistochemical analyses. ⋯ Annexin V localized to the cytoplasm of injured neurons ipsilateral to the site of injury as well as to otherwise normal-appearing neurons of the contralateral hemisphere as confirmed by dual fluorescent microscopy. It is concluded that there is abnormal bilateral, multifocal annexin V uptake, greater on the left than on the right side, within 4 h of unilateral left MCA ischemic injury and that the uptake peaks at 3 days and decreases by 7 days after injury. This pattern suggests that neuronal stress may play a role in the response of the brain to focal injury and be responsible for annexin V uptake outside the region of ischemic insult.
-
Eur. J. Nucl. Med. Mol. Imaging · Apr 2004
Comparative Study Clinical Trial Controlled Clinical TrialValidation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging.
The main aim of this study was to validate the accuracy of 4D-MSPECT in the assessment of left ventricular (LV) end-diastolic/end-systolic volumes (EDV, ESV) and ejection fraction (LVEF) from gated technetium-99m methoxyisobutylisonitrile single-photon emission tomography ((99m)Tc-MIBI SPET), using cardiac magnetic resonance imaging (cMRI) as the reference method. By further comparing 4D-MSPECT and QGS with cMRI, the software-specific characteristics were analysed to elucidate clinical applicability. Fifty-four patients with suspected or proven coronary artery disease (CAD) were examined with gated (99m)Tc-MIBI SPET (8 gates/cardiac cycle) about 60 min after tracer injection at rest. ⋯ For LVEF, 4D-MSPECT and cMRI revealed no significant differences, whereas QGS yielded significantly lower values than cMRI [57.5%+/-13.7% (4D-MSPECT), 52.2%+/-12.4% (QGS), 60.0%+/-15.8% (cMRI)]. In conclusion, agreement between gated (99m)Tc-MIBI SPET and cMRI is good across a wide range of clinically relevant LV volume and LVEF values assessed by 4D-MSPECT and QGS. However, algorithm-varying underestimation of LVEF should be accounted for in the clinical context and limits interchangeable use of software.