IEEE transactions on bio-medical engineering
-
In order for an "artificial pancreas" to become a reality for ambulatory use, a practical closed-loop control strategy must be developed and validated. In this paper, an improved PID control strategy for blood glucose control is proposed and critically evaluated in silico using a physiologic model of Hovorka et al. [1]. The key features of the proposed control strategy are: 1) a switching strategy for initiating PID control after a meal and insulin bolus; 2) a novel time-varying setpoint trajectory; 3) noise and derivative filters to reduce sensitivity to sensor noise; and 4) a practical controller tuning strategy. Simulation results demonstrate that proposed control strategy compares favorably to alternatives for realistic conditions that include meal challenges, incorrect carbohydrate meal estimates, changes in insulin sensitivity, and measurement noise.
-
IEEE Trans Biomed Eng · Mar 2008
A quantitative method based on total relative change for dynamic electrical impedance tomography.
We proposed a new method based on total relative change (TRC) from measured boundary voltages to quantify the volume changes of fluid during electrical impedance tomography (EIT) monitoring. The results showed that TRC linearly correlated with the volume of infused saline solution into a phantom, and the slope of TRC changes was approximately linear with the infusion speed. A inserted copper tube at different positions did not affect TRC significantly. The linear relationship between TRC and volume change indicates that TRC could be a good quantitative index for dynamic EIT.
-
IEEE Trans Biomed Eng · Mar 2008
Tracking the time-varying cortical connectivity patterns by adaptive multivariate estimators.
The directed transfer function (DTF) and the partial directed coherence (PDC) are frequency-domain estimators that are able to describe interactions between cortical areas in terms of the concept of Granger causality. However, the classical estimation of these methods is based on the multivariate autoregressive modelling (MVAR) of time series, which requires the stationarity of the signals. In this way, transient pathways of information transfer remains hidden. ⋯ An SNR of five and a number of trials of at least 20 provide a good accuracy in the estimation. After testing the method by the simulation study, we provide an application to the cortical estimations obtained from high resolution EEG data recorded from a group of healthy subject during a combined foot-lips movement and present the time-varying connectivity patterns resulting from the application of both DTF and PDC. Two different cortical networks were detected with the proposed methods, one constant across the task and the other evolving during the preparation of the joint movement.
-
IEEE Trans Biomed Eng · Mar 2008
Error-related EEG potentials generated during simulated brain-computer interaction.
Brain-computer interfaces (BCIs) are prone to errors in the recognition of subject's intent. An elegant approach to improve the accuracy of BCIs consists in a verification procedure directly based on the presence of error-related potentials (ErrP) in the electroencephalogram (EEG) recorded right after the occurrence of an error. Several studies show the presence of ErrP in typical choice reaction tasks. ⋯ Five healthy volunteer subjects participated in a new human-robot interaction experiment, which seem to confirm the previously reported presence of a new kind of ErrP. However, in order to exploit these ErrP, we need to detect them in each single trial using a short window following the feedback associated to the response of the BCI. We have achieved an average recognition rate of correct and erroneous single trials of 83.5% and 79.2%, respectively, using a classifier built with data recorded up to three months earlier.
-
A new class of spatial filters for surface electromyographic (EMG) signal detection is proposed. These filters are based on the 2-D spatial wavelet decomposition of the surface EMG recorded with a grid of electrodes and inverse transformation after zeroing a subset of the transformation coefficients. The filter transfer function depends on the selected mother wavelet in the two spatial directions. ⋯ For example, in simulation, the ratio between the peak-to-peak amplitude of action potentials generated by motor units 20 degrees apart in the transversal direction was 8.58% (with monopolar recording), 2.47% (double differential), 2.59% (normal double differential), and 0.47% (optimized wavelet filter). In experimental recordings, the duration of the detected action potentials decreased from (mean +/- SD) 6.9 +/- 0.3 ms (monopolar recording), to 4.5 +/- 0.2 ms (normal double differential), 3.7 +/- 0.2 (double differential), and 3.0 +/- 0.1 ms (optimized wavelet filter). In conclusion, the new class of spatial filters with the proposed signal-based optimization of the transfer function allows better discrimination of individual motor unit activities in surface EMG recordings than it was previously possible.