Neuronal network morphology and electrophysiologyof hippocampal neurons cultured on surface-treated multielectrode arrays.
Toward the development of biocompatible surfaces for implantable electrode arrays and the creation of patterned neuronal networks, the impact of select biochemical substrates [poly-D-lysine (PDL), polyornithine (PO), polyethylenimine (PEI), and a basement membrane extract (BM)] on network morphology and spontaneous electrophysiological activity of dissociated hippocampal neurons was investigated. Cultured in serum-free Neurobasal medium at 100 000 cells/cm(2), neurons attached to each substrate. PDL, PO, and PEI induced little or no neuronal clustering and process fasciculation, whereas the addition of BM promoted these features. ⋯ Synchronized bursting was highly correlated with neuronal clustering and process fasciculation. Spike amplitude was negatively correlated with thin branching which was most evident in neurons grown on PEI. These data indicate that factors, which influence adherence of neurons to surfaces, can profoundly impact both neuronal network morphology and electrophysiological activity in vitro.
-
IEEE Trans Biomed Eng · Jun 2007
Image processing for a high-resolution optoelectronic retinal prosthesis.
In an effort to restore visual perception in retinal diseases such as age-related macular degeneration or retinitis pigmentosa, a design was recently presented for a high-resolution optoelectronic retinal prosthesis having thousands of electrodes. This system requires real-time image processing fast enough to convert a video stream of images into electrical stimulus patterns that can be properly interpreted by the brain. Here, we present image-processing and tracking algorithms for a subretinal implant designed to stimulate the second neuron in the visual pathway, bypassing the degenerated first synaptic layer. ⋯ Methods to accelerate real-time transformations include the exploitation of data redundancy in the time domain, and the use of precomputed lookup tables that are adjustable to retinal physiology and allow flexible control of stimulation parameters. A software implementation of these algorithms processes natural visual scenes with sufficient speed for real-time operation. This computationally efficient algorithm resembles, in some aspects, biological strategies of efficient coding in the retina and could provide a refresh rate higher than fifty frames per second on our system.
-
IEEE Trans Biomed Eng · Jun 2007
Neurobiological assessment of regenerative electrodes for bidirectional interfacing injured peripheral nerves.
Regenerative electrodes are designed to interface regenerated axons from a sectioned peripheral nerve. Applicability of regenerative electrodes depends on biocompatibility, success of axonal regeneration, secondary nerve damage, and adequacy of interface electronics. Polyimide sieve electrodes with 281 holes were chronically implanted in the severed sciatic nerve of 30 rats. ⋯ The number of regenerated axons increased thanks to the larger open area. Recordings were obtained from a low proportion of electrodes on the sieve in response to distal stimulation. Difficulties for recording impulses with regenerative electrodes include the small size of regenerated axons, changes in membrane excitability and in target reconnection.
-
IEEE Trans Biomed Eng · Jun 2007
Performance of multisite silicon microprobes implanted chronically in the ventral cochlear nucleus of the cat.
A central auditory prosthesis based on microstimulation within the ventral cochlear nucleus (VCN) offers a means of restoring hearing to persons whose auditory nerve has been destroyed bilaterally and cannot benefit from cochlear implants. Arrays of silicon probes with 16 stimulating sites were implanted into the VCN of adult cats, for up to 314 days. Compound neuronal responses evoked from the sites in the VCN were recorded periodically in the central nucleus of the contralateral inferior colliculus (ICC). ⋯ Multiunit neuronal activity evoked from the stimulating sites in the VCN was recorded along the dorsolateral-ventromedial (DLVM) axis of the ICC. The distribution, span and degree of overlap of the multiunit activity demonstrated the utility of the multisite, multishank array configuration as a means of accessing the neuronal populations in the VCN that encode various acoustic frequencies. These findings are encouraging for the prospects of developing an auditory prosthesis employing multi-site silicon microprobes.
-
IEEE Trans Biomed Eng · May 2007
Detrended fluctuation analysis of EEG as a measure of depth of anesthesia.
For several decades, a number of methods have been developed for the noninvasive assessment of the level of consciousness during general anesthesia. In this paper, detrended fluctuation analysis is used to study the scaling behavior of the electroencephalogram as a measure of the level of consciousness. ⋯ Two of them present a good correlation with established indexes of depth of anesthesia. The scaling behavior has been found related to the depth of anesthesia and the methodology allows real-time implementation, which enables its application in monitoring devices.