Interactive cardiovascular and thoracic surgery
-
Interact Cardiovasc Thorac Surg · Dec 2011
Comparative StudyA comparison of external and internal jugular venous pressures to monitor pulmonary artery pressure after superior cavopulmonary anastomosis.
The internal jugular vein continues to be the preferred site for cannulation to monitor central venous pressure despite the reported evidence of the accuracy of external jugular venous pressure (EJVP) to reliably predict internal jugular venous pressure (IJVP). Internal jugular venous cannulation carries a risk of thrombosis that can be life-threatening in children undergoing superior cavopulmonary anastomosis and a subsequent Fontan procedure. The present study compared IJVP and EJVP in children undergoing superior cavopulmonary anastomosis and found no statistical and clinical difference between IJVP and EJVP. Thus, external jugular vein cannulation reliably predicts IJVP and pulmonary artery pressures in children undergoing superior cavopulmonary anastomosis, and may obviate the risk of life-threatening cavopulmonary thrombosis.
-
Interact Cardiovasc Thorac Surg · Dec 2011
Preliminary experience in the use of an extracellular matrix to repair congenital heart diseases.
Congenital heart diseases are corrected early in life, so the surgical procedure has to maintain the maximum potential for growth. The quest for the ideal material for cardiac tissue repair is still ongoing. Here, we describe our preliminary experience with an extracellular matrix for cardiac and vascular tissue repair. ⋯ In the last 25 months, we used an extracellular matrix for cardiac and vascular tissue repair. The patch is advocated to induce the patient's own tissue regeneration. The early results are encouraging, but a longer follow-up is needed to understand the real potential of this material.
-
Interact Cardiovasc Thorac Surg · Dec 2011
Postoperative non-invasive assessment of pulmonary vascular resistance using Doppler echocardiography.
Non-invasive monitoring of pulmonary vascular resistance (PVR) in postoperative cardiac surgery patients might be useful, particularly for management of pulmonary hypertension. For this purpose, we sought to assess Doppler echocardiography in the intensive care setting. In 73 patients, hemodynamics was measured using both, invasive gold standard (pulmonary artery catheter), and non-invasively by Doppler echocardiography. ⋯ Strain correlated with PVR in group 2 patients only. TRV/VTI(RVOT) and tricuspid annular systolic velocity (S'), are useful for non-invasive monitoring of PVR in postoperative cardiac surgery patients with or without elevated left ventricular filling pressure. Strain may be used in patients with elevated filling pressure.