Journal of occupational and environmental hygiene
-
J Occup Environ Hyg · Jan 2014
Effect of upper strap downward displacement on n95 filtering facepiece respirator fit factors: a pilot study.
Fifteen subjects underwent three replicates of quantitative respirator fit-testing with N95 filtering facepiece respirators that were donned with the upper strap high on the occiput, as per the manufacturers' donning instructions. Each fit-test was immediately followed by repeat fit-testing with the upper strap downwardly displaced to the level of the ear sulcus to determine any change in fit factors that might occur with upper strap downward slippage. ⋯ Geometric mean fit factors for the initial passed fit-tests, and following downward strap displacement, were 217 ± 1.6 and 207 ± 1.9, respectively (p = 0.64). Downward displacement of the top strap did not significantly impact fit factors of N95 FFRs that had previously passed fit-testing.