The Journal of bone and joint surgery. American volume
-
J Bone Joint Surg Am · Apr 2004
Comparative StudyLateral-entry pin fixation in the management of supracondylar fractures in children.
There has been controversy regarding the optimal pin configuration in the management of supracondylar humeral fractures in children. A crossed-pin configuration may be mechanically more stable than lateral pins in torsional loading, but it is associated with a risk of iatrogenic injury to the ulnar nerve. Previous clinical studies have suggested that lateral pins provide sufficient fixation of unstable supracondylar fractures. However, these studies were retrospective and subject to patient-selection bias. ⋯ In this large, consecutive series without selection bias, the use of lateral-entry pins alone was effective for even the most unstable supracondylar humeral fractures. There were no iatrogenic ulnar nerve injuries, and no reduction was lost. The important technical points for fixation with lateral-entry pins are (1) maximize separation of the pins at the fracture site, (2) engage the medial and lateral columns proximal to the fracture, (3) engage sufficient bone in both the proximal segment and the distal fragment, and (4) maintain a low threshold for use of a third lateral-entry pin if there is concern about fracture stability or the location of the first two pins.
-
J Bone Joint Surg Am · Mar 2004
Comparative StudyStability analysis of craniovertebral junction fixation techniques.
Craniovertebral arthrodesis in the upper cervical spine is challenging because of the high degree of mobility afforded by this region. A novel method for achieving atlantoaxial fixation with use of polyaxial screws inserted bilaterally into the lateral masses of C1 and transpedicularly into C2 with longitudinal rod connection has recently been introduced. The question remains as to whether this technique provides adequate stability when extended cephalad to include the occiput. The purpose of this study was to determine the primary stability afforded by this novel construct and compare its stability with the current standard of bilateral longitudinal plates combined with C1-C2 transarticular screws. ⋯ Both hardware systems provide equivalent construct stability in the immediate postoperative period when it is critical for the eventual success of a craniovertebral arthrodesis. On the basis of this work, we believe that the decision to use either construct should be determined by clinical rather than biomechanical concerns.
-
J Bone Joint Surg Am · Mar 2004
The relationship between surgeon and hospital volume and outcomes for shoulder arthroplasty.
As far as we know, no previous study has determined the relationship between volume and outcomes for shoulder arthroplasty. We hypothesized that surgeons and hospitals with higher caseloads of total shoulder arthroplasties and hemiarthroplasties have better outcomes as measured by decreased mortality rate, shorter length of stay in the hospital, reduced postoperative complications, and routine disposition of patients on discharge. ⋯ Therapeutic study, Level III-2 (retrospective cohort study). See Instructions to Authors for a complete description of levels of evidence.
-
J Bone Joint Surg Am · Mar 2004
Posterior slope of the tibial implant and the outcome of unicompartmental knee arthroplasty.
Laboratory studies have suggested that the sagittal displacements permitted by a knee replacement are influenced by the posterior slope of the tibial implant. The effect of the posterior slope of the tibial implant on the outcome of unicompartmental arthroplasty is not well known. The purpose of the present study was to assess the effect of the posterior slope on the long-term outcome of unicompartmental arthroplasty in knees with intact and deficient anterior cruciate ligaments. ⋯ Prognostic study, Level II-1 (retrospective study). See Instructions to Authors for a complete description of levels of evidence.