Journal of neurosurgery. Spine
-
Pedicle screw fixation is a standard procedure of spinal instrumentation, but accurate screw placement is essential to avoid injury to the adjacent structures, such as the vessels, nerves, and viscera. The authors recently developed an intraoperative screw guiding method in which patient-specific laminar templates were used, and verified the accuracy of the multistep procedure in the thoracic spine. ⋯ The multistep, patient-specific screw guide template system is useful for intraoperative pedicle screw navigation in the thoracic spine. This simple and economical method can improve the accuracy of pedicle screw insertion and reduce the operating time and radiation exposure of spinal fixation surgery.
-
Case Reports
Rectocutaneous fistula and nonunion after TranS1 axial lumbar interbody fusion L5-S1 fixation: case report.
The authors report a case of rectal injury, rectocutaneous fistula, and pseudarthrosis after a TranS1 axial lumbar interbody fusion (AxiaLIF) L5-S1 fixation. The TranS1 AxiaLIF procedure is a percutaneous minimally invasive approach to transsacral fusion of the L4-S1 vertebral levels. It is gaining popularity due to the ease of access to the sacrum through the presacral space, which is relatively free from intraabdominal and neurovascular structures. ⋯ A CT fistulagram and flexible sigmoidoscopy showed evidence of rectocutaneous fistula, which was managed with intravenous antibiotic therapy and bowel rest with total parenteral nutrition. Subsequent studies performed 6 months postoperatively revealed evidence of pseudarthrosis. The patient's rectocutaneous fistula symptoms gradually subsided, but his preoperative back pain recurred prompting a revision of his L5-S1 spinal fusion.
-
Case Reports
Early postoperative dislocation of the anterior Maverick lumbar disc prosthesis: report of 2 cases.
The authors report on 2 cases of anterior dislocation of the Maverick lumbar disc prosthesis, both occurring in the early postoperative period. These cases developed after experience with more than 50 uneventful cases and were therefore thought to be unrelated to the surgeon's learning curve. No similar complications have been previously reported. ⋯ Surgeons should be aware of the risk of anterior dislocation of the Maverick prosthesis. Keel cutters should be regularly checked for sharpness, as they may be implicated in the loosening of implants. Patients and their physical therapists should also avoid lumbar hyperextension in the early postoperative period.
-
Persistent cough due to irritation of the vagus nerve by osteophytes resulting from cervical spinal surgery is a very rare condition. The authors report the case of a 49-year-old woman who presented with a persistent cough subsequent to cervical spinal surgery. One year after the initial operation, the patient underwent surgery to free the larynx from the prevertebral fascia and cut the pharyngeal plexus, but her symptoms persisted. ⋯ The osteophyte was resected and the vagus nerve was moved to a position anterior to the carotid artery and was isolated by means of an autogenous tensor fascia lata graft. The patient's symptom disappeared immediately after the surgery. At the most recent follow-up visit, 18 months after surgery, the patient was symptom free and was pursuing regular daily activities without using a cervical collar.
-
Case Reports
En bloc resection of a multilevel high-cervical chordoma involving C-2: new operative modalities: technical note.
En bloc resection of cervical chordomas has led to longer survival rates but has resulted in significant morbidities from the procedure, especially when the tumor is multilevel and located in the high-cervical (C1-3) region. To date, there have been only 5 reported cases of multilevel en bloc resection of chordomas in the high-cervical spine. ⋯ A complete spondylectomy was performed at C-2 and C-3 with spinal reconstruction and stabilization, using several new modalities that were not used in the previous cases. The use of 1) preoperative endovascular sacrificing of the vertebral artery, 2) CT image-guidance, 3) an ultrasonic aspirator for skeletonizing the vertebral artery, and 4) the custom design of an anterior cage all contributed to absence of intraoperative or long-term (20 months) hardware failure and pseudarthrosis.