Journal of biomechanics
-
Journal of biomechanics · Sep 2013
ReviewWhat have we learned from finite element model studies of lumbar intervertebral discs in the past four decades?
Finite element analysis is a powerful tool routinely used to study complex biological systems. For the last four decades, the lumbar intervertebral disc has been the focus of many such investigations. To understand the disc functional biomechanics, a precise knowledge of the disc mechanical, structural and biochemical environments at the microscopic and macroscopic levels is essential. ⋯ The role of fluid pressurization and collagen fiber stiffening diminish with time during diurnal loading. The endplates permeability influences the time-dependent response of the disc in both loaded and unloaded recovery phases. The transport of solutes is substantially influenced by the disc size, tissue diffusivity and endplates permeability.
-
Journal of biomechanics · Sep 2013
Computational biomechanics of a lumbar motion segment in pure and combined shear loads.
Anterior shear has been implicated as a risk factor in spinal injuries. A 3D nonlinear poroelastic finite element model study of a lumbar motion segment L4-L5 was performed to predict the temporal shear response under various single and combined shear loads. Effects of nucleotomy and facetectomy as well as changes in the posture and facet gap distance were analyzed as well. ⋯ The shear resistance of the motion segment remains almost the same with time despite the transfer of load sharing from the disc to facets. Large forces on facet joints are computed especially under greater compression preloads, shear forces and extension rotations, as time progresses and with smaller gap distances. The disc contribution on the other hand increases under larger shear loads, smaller compression preloads, flexed postures, larger facet gap distances and at transient periods.
-
Journal of biomechanics · Sep 2013
Prediction of ground reaction forces during gait based on kinematics and a neural network model.
Kinetic information during human gait can be estimated with inverse dynamics, which is based on anthropometric, kinematic, and ground reaction data. While collecting ground reaction data with a force plate is useful, it is costly and requires regulated space. The goal of this study was to propose a new, accurate methodology for predicting ground reaction forces (GRFs) during level walking without the help of a force plate. ⋯ The high correlation coefficients(R) are due to the improvement of the prediction rate in the double support phase. This study also proved the possibility of calculating joint forces and moments based on the GRFs predicted with the proposed new hybrid method. Data generated with the proposed method may thus be used instead of raw GRF data in gait analysis and in calculating joint dynamic data using inverse dynamics.
-
Journal of biomechanics · Sep 2013
On the accuracy of the Head Impact Telemetry (HIT) System used in football helmets.
On-field measurement of head impacts has relied on the Head Impact Telemetry (HIT) System, which uses helmet mounted accelerometers to determine linear and angular head accelerations. HIT is used in youth and collegiate football to assess the frequency and severity of helmet impacts. This paper evaluates the accuracy of HIT for individual head impacts. ⋯ HIT data were compared to data from the Hybrid III equipped with a 3-2-2-2 accelerometer array. The absolute and root mean square error (RMSE) for HIT were computed for each impact (n=90). Fifty-five percent (n=49) had an absolute error greater than 15% while the RMSE was 59.1% for peak linear acceleration.
-
Journal of biomechanics · Sep 2013
Energy cost of balance control during walking decreases with external stabilizer stiffness independent of walking speed.
Human walking requires active neuromuscular control to ensure stability in the lateral direction, which inflicts a certain metabolic load. The magnitude of this metabolic load has previously been investigated by means of passive external lateral stabilization via spring-like cords. In the present study, we applied this method to test two hypotheses: (1) the effect of external stabilization on energy cost depends on the stiffness of the stabilizing springs, and (2) the energy cost for balance control, and consequently the effect of external stabilization on energy cost, depends on walking speed. ⋯ Increasing stabilizer stiffness increased the effects on both energy cost and medio-lateral gait parameters up to a stiffness of 1260 Nm(-1). Contrary to expectations, the effect of stabilization was independent of walking speed (p=0.111). These results show that active lateral stabilization during walking involves an energetic cost, which is independent of walking speed.