Journal of biomechanics
-
Journal of biomechanics · Aug 2011
Modeling leaflet correction techniques in aortic valve repair: A finite element study.
In aortic valve sparing surgery, cusp prolapse is a common cause of residual aortic insufficiency. To correct cusp pathology, native leaflets of the valve frequently require adjustment which can be performed using a variety of described correction techniques, such as central or commissural plication, or resuspension of the leaflet free margin. The practical question then arises of determining which surgical technique provides the best valve performance with the most physiologic coaptation. ⋯ On the one hand, the existing leaflet correction techniques were shown not to adversely affect the dynamic properties of the repaired valves. On the other hand, leaflet resuspension appeared as the best technique compared to central or commissural leaflet plication. It was the only method able to achieve symmetric competence and fix an individual leaflet prolapse while simultaneously restoring normal values for mechanical stress, valve orifice area and coaptation area.
-
Journal of biomechanics · Jul 2011
Entrapment of adult fingers between window glass and seal entry of a motor vehicle side door: an experimental study for investigation of the force at the subjective pain threshold.
In modern motor vehicles with automatic power windows, a potential hazard exists for jam events of fingers between the window glass and seal entry. This study determined entrapment forces acting on adult fingers at the subjective maximum pain threshold during entrapment in such windows. The length and the girth of the proximal and distal interphalangeal joints of the triphalangeal fingers of the right hands of 109 participants (60 men, 49 women) were measured; the diameter was calculated from girth, which was assumed to be circular. ⋯ The maximum bearable entrapment force was 97.2 ± 51.8 N for the PIPs, 43.4 ± 19.9 N for the iPIP, and 36.9 ± 17.8 N for the iDIP. The positive correlation between finger diameter and maximum entrapment force was significant. Particularly with regard to the risk to children's fingers, the 100 N statutory boundary value for closing force of electronic power windows should be reduced.
-
Journal of biomechanics · Jul 2011
Low pulse pressure with high pulsatile external left ventricular power: influence of aortic waves.
Elevated pulse pressure (pp) is considered to be a risk factor for adverse cardiovascular events since it is directly related to an elevated myocardial workload. Information about both pressure and flow wave must be provided to assess hemodynamic complexity and true level of external left ventricular power (ELVP). pp value as a single feature of aortic waves cannot identify true level of ELVP. However, it is generally presumed that ELVP (and consequently LV workload) is positively correlated with pp. ⋯ However, for a given cardiac output, mean pressure, and location of total reflection site, we have found cases where the above-mentioned trend does not hold. Our results suggest that using pp as a single index can result in an underestimation of the LV power demand under certain conditions related to the altered wave dynamics. Hence, in hypertensive patients, a full analysis of aortic wave dynamics is essential for the prevention and management of left ventricular hypertrophy (LVH) and congestive heart failure.
-
Journal of biomechanics · Jul 2011
Viscoelastic properties of human cerebellum using magnetic resonance elastography.
The cerebellum has never been mechanically characterised, despite its physiological importance in the control of motion and the clinical prevalence of cerebellar pathologies. The aim of this study was to measure the linear viscoelastic properties of the cerebellum in human volunteers using Magnetic Resonance Elastography (MRE). ⋯ These data represent the first available data on the viscoelastic properties of cerebellum, which suggest that the cerebellum is less physically stiff than the cerebrum, possibly leading to a different response to mechanical loading. These data will be useful for modelling of the cerebellum for a range of purposes.
-
Journal of biomechanics · Apr 2011
Leg stiffness increases with speed to modulate gait frequency and propulsion energy.
Bipedal walking models with compliant legs have been employed to represent the ground reaction forces (GRFs) observed in human subjects. Quantification of the leg stiffness at varying gait speeds, therefore, would improve our understanding of the contributions of spring-like leg behavior to gait dynamics. In this study, we tuned a model of bipedal walking with damped compliant legs to match human GRFs at different gait speeds. ⋯ The theoretical leg stiffness that maximizes the elastic energy stored in the compliant leg at the end of the single support phase is approximated by the empirical leg stiffness used to match model GRFs to human GRFs. This result implies that the CoM momentum change during the double support phase requires maximum forward propulsion and that an increase in leg stiffness with speed would beneficially increase the propulsion energy. Our results suggest that humans emulate, and may benefit from, spring-like leg mechanics.