Compliance with Guidelines and Efficacy of Heart Rate Monitoring during Newborn Resuscitation: A Prospective Video Study.
Newborn resuscitation guidelines recommend initial assessment of heart rate (HR) and initiation of positive pressure ventilation (PPV) within 60 s after birth in non-breathing newborns. Pulse oximeter (PO) and electrocardiogram (ECG) are suggested methods for continuous HR monitoring during resuscitation. Our aim was to evaluate compliance with guidelines and the efficacy of PO versus ECG monitoring in real-life newborn resuscitations. ⋯ Initial HR assessment and initiation of PPV were achieved within 60 s after birth in only 1/3 of newborn resuscitations. When applied for continuous HR monitoring, ECG was superior to PO in time to achieve reliable HR signals in real-life resuscitations.
-
Nasal continuous positive airway pressure (NCPAP) is a well-studied treatment for respiratory problems in preterm infants. However, the best strategy for NCPAP weaning is unknown. ⋯ Sudden wean of NCPAP was associated with a lower PMA at successful wean compared to pressure wean but also with a lower rate of successful wean at first attempt, most likely because of the developmental stage at which weaning is possible.
-
Case Reports
Neonates Hospitalized with Community-Acquired SARS-CoV-2 in a Colorado Neonatal Intensive Care Unit.
The novel coronavirus 2019 (SARS-CoV-2) has been well described in adults. Further, the impact on older children and during the perinatal time is becoming better studied. As community spread increases, it is important to recognize that neonates are vulnerable to community spread as well. The impact that community-acquired SARS-CoV-2 has in the neonatal time period is unclear, as this population has unique immunity considerations. ⋯ Infants with community-acquired SARS-CoV-2 may require hospitalization due to rule-out sepsis guidelines if found to have fever and/or hypoxia. Caregivers of neonates should exercise recommended guidelines before contact with neonates to limit community spread of SARS-CoV-2 to this potentially vulnerable population, including isolation, particularly as asymptomatic cases become prevalent.
-
Bioreactance cardiac output (CO) monitors are able to non-invasively and continuously monitor CO. However, as a novel tool to measure CO, it must be proven to be accurate and precise. ⋯ Bioreactance cannot be considered interchangeable with transthoracic echocardiography to measure CO in preterm infants during the transition phase. Agreement between bioreactance and other CO metrics should be assessed before concluding its accuracy or inaccuracy in neonates.
-
Multicenter Study
Evaluation of an Intubation Readiness Score to Assess Neonatal Sedation before Intubation.
Premedication for neonatal intubation facilitates the procedure and reduces stress and physiological disturbances. However, no validated scoring system to assess the effect of premedication prior to intubation is available. ⋯ Preintubation sedation assessment using the IRS can adequately predict optimal conditions during intubation in the majority of neonates. We suggest using the IRS in routine clinical care. Further research combining the IRS with other parameters could further improve the predictability of adequate sedation during intubation.