Neonatology
-
Comparative Study
Comparison of Umbilical Serum Copeptin Relative to Erythropoietin and S100B as Asphyxia Biomarkers at Birth.
Birth asphyxia, estimated to account for a million neonatal deaths annually, can cause a wide variety of neurodevelopmental impairments. There is a need to develop new, swift methods to identify those neonates who would benefit from neuroprotective treatments such as hypothermia. ⋯ In this study population, S100B and erythropoietin were not valid biomarkers of birth asphyxia. In contrast, our work suggests that copeptin has high potential to become a routinely used biomarker for acute birth asphyxia and neonatal distress.
-
Comparative Study
Electrical Cardiometry to Monitor Cardiac Output in Preterm Infants with Patent Ductus Arteriosus: A Comparison with Echocardiography.
Electrical cardiometry (EC) is an impedance-based monitoring that provides noninvasive cardiac output (CO) assessment. Through comparison to transthoracic echocardiography (Echo), the accuracy of EC has been verified. However, left-to-right patent ductus arteriosus (PDA) shunting is a concern because PDA shunts aortic flow to the pulmonary artery and may interfere with EC in measuring CO. ⋯ EC and Echo have a wide but clinically acceptable agreement in measuring CO in preterm infants with hsPDA. However, for infants with high CO or ventilated by high-frequency ventilation, interpretation of COEC should be approached with caution.
-
In infants with left-sided obstructive lesions (LSOL), the presence of retrograde blood flow in either the ascending or descending aorta may lead to diminished cerebral and renal blood flow, respectively. ⋯ Retrograde blood flow in the ascending aorta was not associated with cerebral oxygenation, while diastolic backflow in the descending aorta was not associated with renal oxygenation in infants with LSOL.
-
Observational Study
Direct Measurement of Tissue Oxygenation in Neonates via Resonance Raman Spectroscopy: A Pilot Study.
The ability to monitor tissue oxygenation in neonates remains a challenge due to limited blood supply and the reliance on invasive procedures. Resonance Raman spectroscopy noninvasively measures tissue oxygenation (RRS-StO2). Peripheral tissue oxygenation using this novel technology has not been described in neonates. ⋯ Neonatal RRS-StO2 measurements are feasible short term but do not correlate with ScvO2 and SpO2. Healthy neonates had greater differences and variability in RRS-StO2 values, illustrating an evolving microcirculation not detected with pulse oximetry. Greater RRS-StO2 variability in sick neonates requiring respiratory support may indicate microcirculatory instability despite being within target SpO2 ranges. Further study is needed to establish if RRS-StO2 monitoring is an accurate representation of tissue oxygenation.
-
Recently, sustained inflations (SI) during chest compression (CC) (CC+SI) have been suggested as an alternative to the current approach during neonatal resuscitation. No previous study compared CC+SI using CC rates of 90/min to the current 3:1 compression:ventilation ratio (C:V). ⋯ CC+SI during CPR significantly improved ROSC in a porcine model of neonatal resuscitation. This is of considerable clinical relevance because improved respiratory and hemodynamic parameters potentially minimize morbidity and mortality in newborn infants.