The Journal of hand surgery, European volume
-
J Hand Surg Eur Vol · Sep 2014
ReviewComplications following volar locking plate fixation for distal radial fractures: a systematic review.
The purpose of this systematic review is to assess the prevalence of complications following volar locking plate fixation of distal radial fractures. A computer-based search was carried out using EMBASE and PUBMED/MEDLINE. Only prospective comparative and prospective cohort studies that presented data concerning complications after treatment of distal radial fractures with a volar locking plate in human adults with a minimal follow-up of 6 months were included. ⋯ Thirty three studies were eligible for final assessment. Most complications were problems with nerve and tendon function as well as complex regional pain syndrome. With an overall complication rate of 16.5%, most of which were 'minor' complications and low rates of nonunion and malunion, volar locking plate fixation can be considered a reasonably safe treatment option for patients with distal radial fractures.
-
J Hand Surg Eur Vol · Sep 2014
Comparative StudyComparative clinical study of locking screws versus smooth locking pegs in volar plating of distal radius fractures.
The present study was performed to test the null hypothesis on no difference in stability of fixation after volar plating of intra-articular distal radius fractures (AO C2-C3) with either locking smooth pegs or locking screws in a clinical setting. A retrospective evaluation included adult patients with C2-C3 AO fractures treated with a volar plate with locking smooth pegs or locking screws. Radiographic assessment was performed to evaluate extra- and intra-articular parameters in the early postoperative period and after bone union. ⋯ Both groups had bone fragment displacement after fixation. However, there were no significant differences between the groups either in extra- or intra-articular parameters defined by Kreder et al. (1996). Our study shows that, in a clinical setting, there is no difference in stability fixation between locking screws or smooth locking pegs in C2-C3 distal radius fractures.
-
The distal radioulnar joint is a complex structure necessary for forearm motion and force transmission across the wrist. Anatomic and biomechanical advances have revealed broad contributions to distal radioulnar joint stability and refined our understanding of the forces acting across it. ⋯ Treatment strategies include percutaneous, arthroscopic, soft-tissue, osteotomy and arthroplasty techniques. The purpose of this article is to review distal radioulnar joint instability and its management.
-
J Hand Surg Eur Vol · Jul 2014
Distal radio-ulnar joint instability in children and adolescents after wrist trauma.
This study retrospectively evaluated the medical records and radiographs of patients younger than aged 25 that were referred for a second opinion due to ulnar-sided wrist pain and persistent distal radio-ulnar (DRU) joint instability. We identified 85 patients with a major wrist trauma before the age of 18. Median age at trauma was 14 years. Median time between trauma and diagnosis of DRUJ instability was 3 years. Sixty-seven patients (79%) had sustained a fracture at the initial trauma. The two most common skeletal injuries related to the DRUJ instability were Salter-Harris type II fractures (24%) and distal radius fractures (19%). In 19 patients (22%), the secondary DRUJ instability was caused by malunion or growth arrest. Eighteen patients (21%) had no fracture; in spite of this, they presented with subsequent symptomatic DRUJ instability. Fourteen of these 18 patients had a triangular fibrocartilage complex (TFCC) tear, confirmed by arthroscopy, open surgery, or magnetic resonance imaging. In conclusion, late DRUJ instability due to wrist fractures or isolated TFCC tears was found to be common in children and adolescents. ⋯ IV.