The American journal of cardiology
-
This study determined whether noninvasive electrical impedance cardiography accurately measures systemic blood flow (cardiac output) in children with congenital heart defects. A total of 37 patients ranging in age from 2 to 171 months underwent complete right- and left-sided heart catheterizations that included simultaneous Fick and impedance measurement of cardiac output. Based on the diagnosis, 4 groups were formed consisting of a control group (n = 11) with no shunts, a group with intracardiac left-to-right shunting and an atrial septal defect (n = 7), another with a ventricular septal defect (n = 12) and an extracardiac left-to-right shunting with patent ductus arteriosus group (n = 7). ⋯ Fick pulmonary blood flow was significantly greater than impedance or Fick systemic flow in all 3 shunt groups. Impedance cardiography accurately measured systemic blood flow in children without shunts or valvular insufficiency. Likewise, systemic blood flow was accurately measured by impedance in the presence of intracardiac left-to-right shunts (atrial and ventricular septal defects) and extracardiac left-to-right shunts (patent ductus arteriosus).(ABSTRACT TRUNCATED AT 250 WORDS)
-
Randomized Controlled Trial Clinical Trial
Influence of long-term metoprolol treatment on early and late exercise test performance after acute myocardial infarction.
The effect of therapy on exercise performance during a 3-year follow-up after acute myocardial infarction (AMI) was evaluated in a double-blind randomized comparison between 154 patients given metoprolol (100 mg twice daily) and 147 patients given placebo. Exercise tests were performed 1.5, 6, 12, 24 and 36 months after AMI. Maximal accomplished workloads were similar in the 2 groups throughout follow-up. ⋯ Exercise-induced ventricular arrhythmias were significantly more common in the placebo group during the initial 6 months. Death, another AMI or both were significantly reduced by metoprolol treatment in patients with exercise-induced ST depression greater than or equal to 1 mm at the 6-week test. In a multiple logistic regression analysis maximal accomplished workload at 6 weeks (p less than 0.026), male sex (relative risk [rr] = 3.57, p = 0.016), previous AMI (rr = 3.07, p = 0.001), therapy with placebo (rr = 2.14, p = 0.007) and left ventricular failure (rr = 2.04, p = 0.023) were shown to carry independent prognostic information as well as exercise-induced ST-depression (greater than or equal to 1 mm) in placebo-treated patients (rr = 2.70, p = 0.01).
-
Radioactive gallium-67 (Ga-67) has been shown to accumulate within areas of pericardial inflammation. The present study estimated prospectively the prevalence and clinical significance of Ga-67 uptake in the heart in 62 patients 10 to 16 days after open-heart surgery. Of 62 patients studied, markedly diffuse Ga-67 uptake was detected in 21 (34%) and focal or mild diffuse uptake in 23 (37%). ⋯ No other clinical, echocardiographic or electrocardiographic indicators of postpericardiotomy syndrome were related to Ga-67 uptake. No patient developed cardiac tamponade or constrictive pericarditis during the 12-week follow-up and the Ga-67 scan results did not predict the occlusion of coronary artery bypass grafts. Thus, pericardial inflammation manifested as Ga-67 uptake is a common finding after open-heart surgery and appears to be a benign condition.
-
Comparative Study
Success of chronic defibrillation and the role of antiarrhythmic drugs with the automatic implantable cardioverter/defibrillator.
Because the automatic internal cardioverter defibrillator's long-term ability to reduce arrhythmic mortality in patients with ventricular tachycardia/fibrillation is unknown, it is important to determine whether the threshold for defibrillation changes over time. Serial defibrillation thresholds were measured in 23 patients over a mean replacement time of 24.8 +/- 7.5 months. In all cases the lead system was a superior vena cava coil to a left ventricular epicardial patch. ⋯ Defibrillation threshold decreased in patients taking no antiarrhythmic drugs or taking class I agents. Thus, the increase in mean defibrillation threshold was the result of an increase in the patients taking amiodarone. These data suggest that at initial implantation lead systems associated with the lowest defibrillation threshold should be used and the defibrillation threshold should be measured at generator change to guarantee an adequate margin of safety.
-
Previous studies have reached conflicting conclusions about whether cardiac arrest due to ventricular tachycardia (VT) or ventricular fibrillation (VF) in acute myocardial infarction (AMI) is of long-term prognostic significance. The mortality rate in 849 patients with confirmed AMI was analyzed. The mortality rate during the initial hospitalization was higher for patients in whom VT/VF occurred (27% vs 7%, p less than 0.001). ⋯ The long-term mortality rate for hospital survivors was not significantly different for patients who had had VT/VF during acute infarction compared with those who had not (19% vs 21%) (mean follow-up 32 months). Thus, cardiac arrest due to ventricular tachyarrhythmia was associated with a higher in-hospital mortality rate but was not a prognostic factor among hospital survivors. Patients resuscitated from primary VT/VF, which characteristically occurs early after AMI, do not have an adverse prognosis.