Journal of nuclear medicine : official publication, Society of Nuclear Medicine
-
The ictal hyperperfusion (compared with the interictal state) of the cerebellum and basal ganglia has not been investigated systematically in patients with temporal lobe epilepsy (TLE). Their ictal perfusion patterns were analyzed in relation to temporal and frontal hyperperfusion during TLE seizures using SPECT subtraction. ⋯ During TLE seizures, hemispheric CH occurred not only in contralateral but also in ipsilateral or bilateral cerebellar hemispheres to the side of seizure origin. Although temporal lobe origin seizures associated with additional frontal hyperperfusion produced more frequent hemispheric CH, seizures showing only temporal hyperperfusion without frontal hyperperfusion could produce BGH and CH. To determine the side of hemispheric CH, the most important factor appears to be the side of BGH, not the side of seizure origin.
-
Comparative Study
Usefulness of 99mTc-ciprofloxacin (infecton) scan in diagnosis of chronic orthopedic infections: comparative study with 99mTc-HMPAO leukocyte scintigraphy.
99mTc-labeled ciprofloxacin (infecton) has been developed for detecting infectious foci, which localize in high concentrations in living bacteria. Other studies performed with various infections in animals and humans have found that infecton is a promising agent with better specificity for bacterial infections than white blood cell (WBC) scans. In this study, we evaluated the efficacy of infecton scintigraphy for detecting chronic bone and joint infections. ⋯ Infecton is a useful agent for detecting infectious foci in bones and joints. Moreover, the infecton scan seems to be a more powerful tool in diagnosing vertebral infections than WBC scintigraphy.
-
Comparative Study
Technegas versus (81m)Kr ventilation-perfusion scintigraphy: a comparative study in patients with suspected acute pulmonary embolism.
81mKr is widely used as a ventilation agent to diagnose pulmonary embolism (PE). However, (81m)Kr is expensive, which limits its continuous availability. Technegas can be an alternative ventilation agent with the advantage of being less expensive and available daily. The aim of this study was to compare the value of technegas with that of (81m)Kr in the detection of PE. ⋯ In comparison with (81m)Kr, technegas does not result in more false-positive V/Q lung scan results. The use of technegas, however, increases the number of nondiagnostic V/Q lung scan results, which would increase the demand for further additional testing to confirm or refute PE.
-
Comparative Study
Comparison of (18)F-FDG, (131)I-Na, and (201)Tl in diagnosis of recurrent or metastatic thyroid carcinoma.
There are several reports about the usefulness of (18)F-FDG PET in thyroid cancer. However, few studies have compared FDG PET with (131)I and (201)Tl scintigraphy. The aim of this study was to evaluate the clinical significance of whole-body FDG PET in differentiated thyroid cancer and to compare the results with those obtained from (131)I and (201)Tl scintigraphy. ⋯ These data indicate that for detecting metastatic lesions, FDG PET and (131)I scintigraphy may provide complementary information, whereas FDG PET may provide results similar to those of (201)Tl scintigraphy. Thus, the combination of (131)I scintigraphy and FDG PET (or (201)Tl scintigraphy) is the method of choice for detecting metastatic thyroid cancer after total thyroidectomy.