Journal of nuclear medicine : official publication, Society of Nuclear Medicine
-
Comparative Study
Performance characteristics of a newly developed PET/CT scanner using NEMA standards in 2D and 3D modes.
This study evaluates the 2-dimensional (2D) and 3-dimensional (3D) performance characteristics of a newly developed PET/CT scanner using the National Electrical Manufacturers Association (NEMA) NU 2-1994 (NU94) and NEMA NU 2-2001 (NU01) standards. The PET detector array consists of 10,080 individual bismuth germanate crystals arranged in 24 rings of 420 crystals each. The size of each crystal is 6.3 x 6.3 x 30 mm in the axial, transaxial, and radial dimensions, respectively. The PET detector ring diameter is 88.6 cm with axial and transaxial fields of view (FOVs) of 15.7 and 70 cm, respectively. The scanner has a uniform patient port of 70 cm throughout the PET and CT FOV, and the PET scanner is equipped with retractable septa to allow 2D and 3D imaging. ⋯ The results show excellent system sensitivity with relatively uniform resolution throughout the FOV, making this scanner highly suitable for whole-body studies.
-
Letter Practice Guideline Guideline
Exemption of radiopharmaceuticals from <797>.
-
Recombinant human thyroid-stimulating hormone (rhTSH) recently was introduced as a radioiodine administration adjunct that avoids levothyroxine (LT-4) withdrawal and resultant hypothyroidism. The pharmacokinetics of 131I after rhTSH administration are known to differ from those after LT-4 withdrawal but are largely nondelineated in the radioiodine therapy setting. We therefore sought to calculate the red marrow absorbed dose of high therapeutic activities of 131I given after rhTSH administration to patients with metastatic or inoperable locally recurrent differentiated thyroid cancer. We also sought to evaluate the clinical and laboratory effects of this therapy on the bone marrow. ⋯ Our specific findings imply that when clinically warranted, rhTSH should allow an increase in the therapeutic radioiodine activity. Such an increase might improve efficacy while preserving safety and tolerability; this possibility should be assessed in further studies.
-
Randomized Controlled Trial Comparative Study Clinical Trial
Superiority of 3-dimensional stereotactic surface projection analysis over visual inspection in discrimination of patients with very early Alzheimer's disease from controls using brain perfusion SPECT.
In Alzheimer's disease (AD), regional cerebral blood flow (rCBF) in the posterior cingulate gyri and precunei has been reported to decrease even at a very early stage. It may be helpful to use statistical image analysis to distinguish slight decreases in rCBF in this area. We compared a 3-dimensional stereotactic surface projection (3D-SSP) technique with visual inspection in the discrimination of patients with very early AD from age-matched controls using brain perfusion SPECT. ⋯ The ability of 3D-SSP to discriminate patients with very early AD from control subjects is superior to that of visual inspection. It is clinically useful and reliable to adopt the use of 3D-SSP as an adjunct to visual interpretation.