The Targon FN implant was developed in 2007 to treat intracapsular neck of femur fractures. Early results from the design centre have shown good results in terms of fracture complications. We wished to see if these results can be reproduced in an independent institution. ⋯ Our study shows similar results with those of the design centre and which are superior to those currently found in the literature for the more traditional fixation methods. It also shows that the promising results with this new implant as seen from the design institutions can be reproduced by all cadres of surgeons in non-specialist practice.
-
Wear cannot be completely prevented after total hip arthroplasty. If severe polyethylene (PE) liner wear develops, the so-called catastrophic failure occurs and metallosis develops. We postulated that longevity of the new implant may be affected after revision surgery for metallosis following a catastrophic failure of a PE liner due to the substantial amount of PE wear particles and infiltration of the metal particles in this catastrophic condition. ⋯ The survival rate of revision total hip arthroplasty in patients with metallosis following a catastrophic failure of a PE liner was low.
-
The locking plates are often used for internal fixation of closed tibial fractures. The use of a locking plate as an external fixator is still controversial, particularly for closed fractures. The purpose of this study is to evaluate the results of external fixation using the femoral less invasive stabilization system (LISS) plate in proximal metaphyseal fractures of the tibia. ⋯ For proximal metaphyseal fracture of the tibia, external fixation using the femoral LISS plate is a safe and reliable technique with minimal complications and excellent outcomes. Its advantages include ease of performing the surgery, use of a less invasive technique, and convenience of plate removal after fracture healing.
-
As surgical complications tend to occur more frequently in the beginning stages of a surgeon's career, knowledge of perioperative complications is important to perform a safe procedure, especially if the surgeon is a novice. We sought to identify and describe perioperative complications and their management in connection with minimally invasive transforaminal lumbar interbody fusion (TLIF). ⋯ We found perioperative complications occurred more often in the early period of a surgeon's experience with minimally invasive TLIF. Implant-related complications were common and successfully managed by additional surgeries in this series. We suggest greater caution should be exercised to avoid the potential complications, especially when surgeon is a novice to this procedure.
-
Case Reports
Acromioclavicular septic arthritis and sternoclavicular septic arthritis with contiguous pyomyositis.
Acromioclavicular (AC) and sternoclavicular (SC) septic arthritis with contiguous pyomyositis are rare, especially in immunocompetent individuals. We report a case of septic AC joint with pyomyositis of the deltoid and supraspinatus muscles and a separate case with septic SC joint with pyomysitis of the sternocleidomastoid muscle. Both patients had similar presentations of infections with Staphylococcus aureus and were successfully treated with surgical incision and drainage followed by prolonged antibiotic therapy.