The pipeline embolization device (PED) necessitates dual antiplatelet therapy (APT) to decrease thrombotic complications while possibly increasing bleeding risks. The role of APT dose, duration, and response in patients with hemorrhagic and thromboembolic events warrants further analysis. ⋯ High dose ASA >6 months is associated with fewer permanent thrombotic and hemorrhagic events. Clopidogrel therapy ≤6 months is associated with higher rates of thrombotic events. Loading doses of ASA and clopidogrel were associated with a decreased incidence of hemorrhagic events. PFT did not have any significant association with symptomatic events.
-
Remission of neurovascular conflicts in the cerebellopontine angle in interventional neuroradiology.
To investigate the efficacy of endovascular treatment (EVT) for neurovascular conflicts (NVCs) in the cerebellopontine angle (CPA) caused by intracranial aneurysms (IAs) and intracranial arteriovenous malformations (AVMs), including trigeminal neuralgia, hemifacial spasm, and glossopharyngeal neuralgia. ⋯ EVT is a feasible and less invasive approach for relief of NVCs in the CPA caused by IA or intracranial AVM and could be considered as a therapeutic option in these situations.
-
Comparative Study
Assisted coiling of saccular wide-necked unruptured intracranial aneurysms: stent versus balloon.
Assisted coiling with stents or balloons enables a higher percentage of complete occlusions of saccular unruptured intracranial aneurysms to be achieved with a reasonable complication rate. The aim of this study was to compare stent-assisted coiling and the balloon remodeling technique in terms of efficacy, stability, and safety for the treatment of comparable unruptured saccular intracranial aneurysms. ⋯ Stent-assisted coiling achieved better results in terms of complete occlusion and stability than balloon-assisted coiling with a lower rate of recurrence without being associated with a higher risk of intraprocedural complications. Bifurcational and large to giant aneurysms were associated with higher complication rates and higher recurrence rates, respectively, and still represent a challenge for both techniques.
-
Follow-up of intracranial aneurysms treated by flow diverter with MRI is complicated by imaging artifacts produced by these devices. This study compares the diagnostic accuracy of three-dimensional time-of-flight MR angiography (3D-TOF-MRA) and contrast-enhanced MRA (CE-MRA) at 3 T for the evaluation of aneurysm occlusion and parent artery patency after flow diversion treatment, with digital subtraction angiography (DSA) as the gold standard. ⋯ At 3 T, CE-MRA is superior to 3D-TOF-MRA for the evaluation of aneurysm occlusion and parent artery patency after flow diversion treatment. However, intraluminal evaluation remains difficult with MRA regardless of the sequence used.
-
Traumatic intracranial pseudoaneurysms are a rare but severe complication following arterial injury. Pseudoaneurysm formation can occur secondary to blunt or penetrating trauma or iatrogenic injury. We report a case of traumatic pseudoaneurysm secondary to placement of an intracranial pressure (ICP) monitor. ⋯ A cerebral angiogram confirmed a left-sided distal M4 pseudoaneurysm which was treated by n-butyl cyanoacrylate embolization. Intracranial pseudoaneurysm formation following neurosurgical procedures is uncommon. Delayed intracranial hemorrhage in a region of prior intracranial manipulation, even following a procedure as 'routine' as placement of an ICP monitor, should raise the suspicion for this rare but potentially lethal complication.