Injury
-
Meta Analysis
What makes fixation of femoral neck fractures fail? A systematic review and meta-analysis of risk factors.
This systematic review aims to provide an overview of predictors for failure of treatment of displaced femoral neck fracture (dFNF) with internal fixation and quantify their risk of fixation failure in a meta-analysis. ⋯ This study can help surgeons to choose the preferred treatment for patients with a dFNF and substantiate future algorithms and guidelines for treatment of FNF.
-
Meta Analysis
Plate versus screws fixation for the posterior malleolar fragment in trimalleolar ankle fractures.
The fixation methods of posterior malleolar fracture (PMF) in trimalleolar ankle fractures is still controversial. We aim to compare clinical and radiological outcomes between plate fixation and screws fixation for PMF in trimalleolar ankle fractures. ⋯ Plate fixation might have better articular step-off or gap, compared with "A to P" screws fixation for the posterior malleolus in trimalleolar ankle fractures. Screw fixation could achieve shorter surgical time than plate fixation. However, no significant differences were found in AOFAS scores, arthritis, infection, sural nerve injury and total complication during the comparisons.
-
Currently, minimally invasive internal fixation is recommended for the surgical treatment of unstable pelvic fractures. The premise and difficulty of minimally invasive internal fixation are minimally invasive reduction of fractures. This review aimed to investigate the indications, surgical strategy and techniques, safety, and efficacy of intelligent robot-assisted fracture reduction (RAFR) system of pelvic ring injuries. ⋯ Our new pelvic fracture reduction robot system can complete intelligent and minimally invasive fracture reduction for most patients with unstable pelvic fractures. The system has intelligent reduction position and path planning and realizes stable pelvis control through a unique holding arm and a robotic arm. The operation process will not cause additional damage to the patient, which fully meets the clinical requirements. Our study demonstrated the safety and effectiveness of our robotic reduction system and its applicability and usability in clinical practice, thus paving the way towards Robot minimally invasive pelvic fracture surgeries.
-
Randomized Controlled Trial
Complications of standard versus long cephalomedullary nails in the treatment of unstable extracapsular proximal femoral fractures: A randomized controlled trial.
To compare in a prospective randomized trial the mechanical complications in patients with unstable extracapsular proximal femur fractures without subtrochanteric extension (AO/OTA 31-A2 and 31-A3) METHODS: We prospectively studied 182 patients with unstable extracapsular proximal femur fractures without fractures lines extending more than 3 cm below the lesser trochanter, randomized to receive either a 'standard' (240 mm) nail or a long nail and followed them up for 1 year. ⋯ We recommend the use of standard nails (240 mm) for this group of fractures, since it does not produce more mechanical complications, and it is faster, cheaper and easier to interlock distally.
-
Clavicle fractures are common fractures with a rate of 2-5 percent among fractures. Mid-shaft fractures of the clavicle are more common than the other sites of the clavicle. Traditionally, surgical fixation of clavicle fractures has been performed under General Anesthesia (GA). ⋯ In the current study, 30 patients with clavicle fractures were surgically fixed using the WALANT technique. The obtained results showed that it could be an effective technique for pain control during the operation and also early postoperative period. Moreover, the WALANT technique could be considered safe in patients who are at risk for GA because of medical comorbidities, cervical spine injuries, or other factors that make intubation difficult.