Chest
-
Randomized Controlled Trial Clinical Trial
Heat and moisture exchanger vs heated humidifier during long-term mechanical ventilation. A prospective randomized study.
Adequate humidification of inspired gases with HMEs during long-term MV remains controversial. In this study, a comparison is made between tracheal secretions during long-term MV either with HME or conventional HH. Both the HME and HH groups were similar with respect to age, sex, diagnosis, duration of MV, SAPS and mortality. ⋯ Four and two tube occlusions occurred in HME and HH groups, respectively. Tracheal bacterial colonization was similar in the two groups. Given the advantages of HME (reduced nurses' work and financial cost), HME could be routinely used under cautious surveillance and replaced by HH if difficulty in suctioning occurs.
-
Comparative Study
Practice patterns in the treatment of acutely ill hospitalized asthmatic patients at three teaching hospitals. Variability in resource utilization.
Our objective was to determine the extent to which patterns of diagnostic and therapeutic practice differ among hospitals caring for acutely ill hospitalized asthmatic patients in a single city. ⋯ We conclude that considerable variability exists in the diagnostic evaluation of acutely ill hospitalized asthmatic patients in the three hospitals; little variability exists in the pharmacologic treatment of these patients. In the absence of data on outcome regarding functional improvement and reductions in morbidity, we are unable to recommend a preferred pattern of practice from this study.
-
Cardiopulmonary resuscitation (CPR) is often performed in modern critical care units, but its efficacy has not been evaluated in this setting. It is important to evaluate CPR in critical care units because these patients often have multisystem disorders and suffer from diseases reported to carry a poor outcome after CPR. Inappropriate resuscitation of patients in this setting results in increased cost of care (both financial and emotional), with little tangible benefit. ⋯ The only arrest condition found to be independently associated with outcome following CPR was the duration of resuscitative effort (p less than 0.01). The patients who were successfully resuscitated but died before discharge were not different from the patients who were not successfully resuscitated in any parameter that we evaluated. These results demonstrate that CPR can be successful in the MICU and that there are prearrest and arrest parameters which are useful in identifying those patients most likely to benefit from CPR in the critical care setting.
-
Case Reports
Overwhelming necrotizing tracheobronchitis due to inadequate humidification during high-frequency jet ventilation.
Necrotizing tracheobronchitis (NT) associated with conventional mechanical ventilation or high-frequency jet ventilation (HFJV) is a lesion reported most often in neonates. In most cases, a specific cause is not identified. We describe a case of NT in an adult that occurred during HFJV and was attributable to inadequate humidification.