Biomedizinische Technik. Biomedical engineering
-
Modern surgical departments are characterized by a high degree of automation supporting complex procedures. It recently became apparent that integrated operating rooms can improve the quality of care, simplify clinical workflows, and mitigate equipment-related incidents and human errors. Particularly using computer assistance based on data from integrated surgical devices is a promising opportunity. ⋯ It is based on a protocol specifically addressing the requirements of device-to-device communication, yet also provides solutions for connecting the clinical information technology (IT) infrastructure. We present the concept of a service-oriented medical device architecture (SOMDA) as well as an introduction to the technical specification implementing the SOMDA paradigm, currently being standardized within the IEEE 11073 service-oriented device connectivity (SDC) series. In addition, the Session concept is introduced as a key enabler for safe device interconnection in highly dynamic ensembles of networked medical devices; and finally, some security aspects of a SOMDA are discussed.
-
Cement augmentation of pedicle screws is the gold standard for the stabilization of osteoporotic fractures of the spine. In-screw cement augmentation, in which cement is injected through the cannula, is another option for fracture stabilization of fragility fractures of the sacrum. However, biomechanical superiority of this technique compared to conventional sacroiliac screw fixation has not been tested. ⋯ The augmented screw fixation failed in two of eight pelvises, and the non-augmented screws failed in three of eight pelvises. CT scans showed no leakage of cement. In-screw polymethylmethacrylate (PMMA) augmentation showed no advantage based on measured displacement of the sacrum fractures or stiffness for sacroiliac screw fixation of fragility fractures of the sacrum.
-
Vital parameter monitoring of term and preterm infants during incubator care with self-adhesive electrodes or sensors directly positioned on the skin [e.g. photoplethysmography (PPG) for oxygen saturation or electrocardiography (ECG)] is an essential part of daily routine care in neonatal intensive care units. For various reasons, this kind of monitoring contains a lot of stress for the infants. Therefore, there is a need to measure vital parameters (for instance respiration, temperature, pulse, oxygen saturation) without mechanical or conductive contact. ⋯ PPGI was found to be significantly sensitive to movement artifacts. However, for movement classes 1-4, changes in blood perfusion according to the heart rate (HR) were recovered successfully (Pearson correlation: r=0.9759; r=0.765 if class 5 is included). The study was approved by the Ethics Committee of the Universal Hospital of the RWTH Aachen University, Aachen, Germany (EK 254/13).
-
Medical devices emit alarms when a problem with the device or with the patient needs to be addressed by healthcare personnel. At present, problems with device alarms are frequently discussed in the literature, the main message being that patient safety is compromised because device alarms are not as effective and safe as they should - and could - be. ⋯ Recent publications suggested solutions to alarm-related hazards associated with usage errors based on assumptions on the causal relations between, for example, alarm management and human perception, cognition, and responding. However, although there is face validity in many of these assumptions, future research should provide objective empirical evidence in order to deepen our understanding of the actual causal relationships, and hence improve and expand the possibilities for taking appropriate action.