Anesthesiology
-
Claims against anesthesiologists for eye injuries were analyzed as part of the ASA Closed Claims Project. Eye injury occurred in 3% of all claims in the database (71 of 2,046). The payment frequency for eye injury claims was higher than that for non-eye injury claims (70% vs. 56%; P less than or equal to 0.05). ⋯ The median payment for claim involving movement was 10 times greater than for non-movement claims ($90,000 vs. $9,000; P less than or equal to 0.01). Anesthesiologist reviewers deemed the care rendered in the general anesthesia "movement" claims as meeting standards in only 19% of claims. From the perspective of patient safety, as well as risk management, these data suggest two specific needs: research directed at better understanding of the etiology of corneal abrasion and clinical strategies designed to assure patient immobility during ophthalmic surgery.
-
Comparative Study
Intraoperative echocardiography for evaluation of congenital heart defects in infants and children.
To determine the accuracy, utility, and limitations of intraoperative transesophageal echocardiography (TEE) in infants and children, we performed prebypass and postbypass TEE in 90 children undergoing surgical repair of congenital heart lesions, comparing the results to those obtained using intraoperative epicardial echocardiography and pre- and postoperative precordial echocardiography. Patients ranged in age from 4 days to 21 yr (mean 4.1 yr) and in weight from 3 to 68 kg (mean 15.4 kg). Prebypass, we obtained high-quality, two-dimensional TEE images in 86 patients, with correction of the preoperative precordial diagnosis in 3 and confirmation of the preoperative diagnosis in the rest. ⋯ Regurgitant lesions (n = 30) were identified and their severity evaluated in all patients by both TEE and epicardial imaging. Obstructive lesions (n = 33), excluding those involving the right ventricular outflow tract, were well defined by both echocardiographic approaches. Postbypass, we obtained high-quality, two-dimensional, color and Doppler TEE images in 86 patients and epicardial images in 78 patients.(ABSTRACT TRUNCATED AT 250 WORDS)
-
Train-of-four (TOF) monitoring of neuromuscular block at submaximal current stimulation has been recommended because it is less painful than monitoring at supramaximal stimulation. The measurement error, however, when using submaximal stimulation has not as yet been fully elucidated. The authors therefore quantified the measurement error of TOF monitoring at low currents near the initial threshold for stimulation (ITS) by assessing precision (the difference between duplicated TOF ratios measured at the same current) and accuracy (the difference between TOF ratios at lesser currents and the TOF ratio at 58 mA, which served as the reference standard method). ⋯ Whereas there were no statistical significant differences between the mean TOF ratios at the different currents, the standard deviation increased with decreasing currents (P less than 0.01 at currents less than 40 mA). The precision was acceptable except at ITS, where the limits of precision (mean intracurrent difference in TOF ratio +/- two standard deviations) exceeded 0.05, which was the chosen acceptable difference. The standard deviation of the accuracy was significantly increased at currents less than or equal to ITS + 25 mA (P less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)