Anesthesiology
-
Randomized Controlled Trial Multicenter Study Clinical Trial
Efficacy and safety of intravenous parecoxib sodium in relieving acute postoperative pain following gynecologic laparotomy surgery.
This study tested the hypothesis that an injectable cyclooxygenase (COX)-2-specific inhibitor will be at least as effective and well tolerated as a COX-nonspecific conventional nonsteroidal antiinflammatory drug (NSAID) by comparing the analgesic efficacy and tolerability of one intravenous dose of parecoxib sodium, an injectable prodrug of the novel COX-2-specific inhibitor, valdecoxib, with ketorolac and placebo in postoperative laparotomy surgery patients. Intravenous morphine, 4 mg, was studied as a positive analgesic control. ⋯ Single intravenous doses of parecoxib sodium, 20 mg and 40 mg, have comparable analgesic effects and are well tolerated after laparotomy surgery. Parecoxib sodium appears to be as effective as intravenous ketorolac, 30 mg, and superior to intravenous morphine, 4 mg.
-
Randomized Controlled Trial Clinical Trial
Effect of N2O on sevoflurane vaporizer settings during minimal- and low-flow anesthesia.
Uptake of a second gas of a delivered gas mixture decreases the amount of carrier gas and potent inhaled anesthetic leaving the circle system through the pop-off valve. The authors hypothesized that the vaporizer settings required to maintain constant end-expired sevoflurane concentration (Etsevo) during minimal-flow anesthesia (MFA, fresh gas flow of 0.5 l/min) or low-flow anesthesia (LFA, fresh gas flow of 1 l/min) would be lower when sevoflurane is used in oxygen-nitrous oxide than in oxygen. ⋯ When using oxygen-nitrous oxide as the carrier gas, less gas and vapor are wasted through the pop-off valve than when 100% oxygen is used. During MFA with an oxygen-nitrous oxide mixture, when almost all of the delivered oxygen and nitrous oxide is taken up by the patient, the vaporizer dial setting required to maintain a constant Etsevo is lower than when 100% oxygen is used. With higher fresh gas flows (LFA), this effect of nitrous oxide becomes insignificant, presumably because the proportion of excess gas leaving the pop-off valve relative to the amount taken up by the patient increases. However, other unexplored factors affecting gas kinetics in a circle system may contribute to our observations.
-
The extraction of the middle latency auditory evoked potentials (MLAEP) is usually done by moving time averaging (MTA) over many sweeps (often 250-1,000), which could produce a delay of more than 1 min. This problem was addressed by applying an autoregressive model with exogenous input (ARX) that enables extraction of the auditory evoked potentials (AEP) within 15 sweeps. The objective of this study was to show that an AEP could be extracted faster by ARX than by MTA and with the same reliability. ⋯ The authors conclude that the MLAEP peaks and the AAI correlate well to the MOAAS, whether extracted by MTA or ARX, but the ARX method produced a significantly shorter delay than the MTA.