Anesthesiology
-
Meta Analysis Comparative Study
Anesthetic techniques during surgical repair of femoral neck fractures. A meta-analysis.
Fracture of the hip typically occurs in older women. These patients usually have serious accompanying chronic illnesses. There is a difference of opinion as to the choice of regional versus general anesthesia for surgery in these patients. ⋯ By probability difference, mortality was a non-significant 2.7 percentage points less following regional anesthesia. By odds ratio effect measure, death was 1.5 times more likely following general anesthesia, but the lower bound of the 95% confidence interval was close to 1. Meta-analysis does not allow a conclusion that important differences in mortality exist between regional and general anesthesia for traumatic hip fracture surgery.
-
Sixty-one patients ASA physical status 1-2 aged 1 month to 12 years undergoing elective surgery were included in the study. Anesthesia was induced via a mask with sevoflurane up to 5% and 66% nitrous oxide in oxygen. After paralysis with vecuronium (0.12 mg/kg iv), the trachea was intubated and the lungs were ventilated manually with 3% sevoflurane in oxygen until the end-tidal nitrous oxide decreased to less than 5%. ⋯ The patients with symptomatic upper respiratory infection required less time for Spo2 to decrease to 95% compared to the asymptomatic children. We conclude that younger children require less time for Spo2 to decrease to 95%. The presence of upper respiratory infection is an additional factor increasing the susceptibility of small children to hypoxemia.
-
Sevoflurane, a new inhalational anesthetic agent has been shown to produce degradation products upon interaction with CO2 absorbants. Quantification of these sevoflurane degradation products during low-flow or closed circuit anesthesia in patients has not been well evaluated. The production of sevoflurane degradation products was evaluated using a low-flow anesthetic technique in patients receiving sevoflurane anesthesia in excess of 3 h. ⋯ Mean maximum inhalation concentration of compound A using baralyme was 20.28 +/- 8.6 ppm (mean +/- SEM) compared to 8.16 +/- 2.67 ppm obtained with soda lime, a difference that did not reach statistical significance. A single patient achieved a maximal concentration of 60.78 ppm during low-flow anesthesia with baralyme. Exhalation concentrations of compound A were less than inhalation concentrations, suggesting patient uptake.(ABSTRACT TRUNCATED AT 250 WORDS)
-
Randomized Controlled Trial Comparative Study Clinical Trial
A randomized comparison of intravenous versus lumbar and thoracic epidural fentanyl for analgesia after thoracotomy.
Administration of large doses of fentanyl is a popular method to provide postoperative analgesia after thoracotomy. It is however unclear whether epidural lumbar (L) or epidural thoracic (T) administration of fentanyl confers any major advantage over intravenous (iv) infusion. Using a randomized prospective study design, we compared the potential benefits of L, T, and iv fentanyl administration after thoracotomy in 50 patients. ⋯ There was no difference between the groups in overall quality of analgesia at rest and after coughing, quantity of fentanyl delivered (L = 1.15 +/- 0.38, T = 1.22 +/- 0.23, iv = 1.27 +/- 0.3 micrograms.kg-1.h-1), incidence of pruritus needing treatment (L = 2, T = 1, iv = 0 patients), need to decrease fentanyl infusion rate because of side effects (L = 2, T = 2, iv = 4 patients), importance of pulmonary infiltrates, or arterial blood gas values. One patient (L group) needed naloxone (0.04 mg iv). Intravenous patients were more frequently nauseated (P = .009) and needed boluses of fentanyl more often (L = 3 +/- 9, iv = 6 +/- 12, T = 4 +/- 8; P = .04).(ABSTRACT TRUNCATED AT 250 WORDS)
-
The proliferation of monitors and alarms in the operating room may lead to increased confusion and misdiagnosis unless the information provided is better organized. Intelligent alarm systems are being developed to organize these alarms, on the assumption that they will shorten the time anesthesiologists need to detect and correct faults. This study compared the human response time (the time between the sounding of an alarm and the resolution of a fault) when anesthesiologists used a conventional alarm system and when they used an intelligent alarm system. ⋯ The standard deviations in response time were only half as large for the intelligent alarm system. It appears that the computer-based neural network in the intelligent alarm system diagnosed faults more rapidly and consistently than did the anesthesiologists. This study indicates that breathing circuit faults may be more rapidly corrected when the anesthesiologist is guided by intelligent alarms.