Anesthesia and analgesia
-
Anesthesia and analgesia · Mar 1997
Clinical TrialEfficacy of the self-inflating bulb in differentiating esophageal from tracheal intubation in the parturient undergoing cesarean section.
We studied the efficacy of the self-inflating bulb (SIB) in differentiating tracheal from esophageal intubation in 40 parturients undergoing elective cesarean section under general anesthesia. After induction and muscle relaxation, the trachea was intubated under direct vision with cuffed tube. In 20 parturients, the esophagus was also intubated with an identical tube. ⋯ The incidence of false positive results immediately after induction was 30% with T1 and 35% with T2. The mechanism of false negative responses may be attributed to decreased functional residual capacity leading to reduced caliber of intrathoracic airways and terminal airway closure; whereas false positive responses may be related to an incompetent gastroesophageal junction. We conclude that the SIB is unreliable for differentiating tracheal from esophageal intubation in the parturient undergoing cesarean section.
-
Anesthesia and analgesia · Mar 1997
The association between Doppler transmitral flow variables measured by transesophageal echocardiography and pulmonary capillary wedge pressure.
The association between Doppler transmitral flow variables, measured by transesophageal echocardiography (TEE), and pulmonary capillary wedge pressure (PCWP) was studied in 88 patients undergoing coronary artery surgery. The Doppler flow variables and PCWP were measured after sternotomy by blinded investigators. In the first part of the study, patients were divided into two groups according to left ventricular (LV) ejection fraction (EF): Group A, EF > 35% (n = 38) and Group B, EF < or = 35% (n = 34). ⋯ When the relationship between DCT-E and PCWP was tested prospectively in a third group of patients [Group C; EF < or = 35% (n = 16)], a close agreement between the calculated and measured PCWP (bias = -0.55 +/- 3.87 mm Hg) was noted. The sensitivity, specificity, and positive predictive value of DCT-E > or = 150 ms for PCWP < 10 mm Hg were 93.3%, 100%, and 100%, respectively. In summary, patients with decreased left ventricular systolic function undergoing coronary artery surgery demonstrated high, statistically significant, correlations between PCWP and the deceleration time or deceleration slope of early diastolic filling as measured by transesophageal Doppler echocardiography.
-
Anesthesia and analgesia · Mar 1997
Peripherally administrated morphine attenuates capsaicin-induced mechanical hypersensitivity in humans.
We examined the hypothesis that peripheral morphine can modulate pain and hyperalgesia/allodynia in the human capsaicin model. Subcutaneous injections of 1 mL morphine (1 mg/mL) in one arm and of 1 mL 0.9% saline in the other arm were made prior to bilateral intradermal injections of 50 microL (6 mg/mL) capsaicin. All injections were made on the volar aspect of the arm. ⋯ Capsaicin injection resulted in spontaneous pain on the saline-injected side not significantly different from that on the morphine-injected side. However, capsaicin injections gave rise to significantly less pain evoked by mechanical stimuli, as well as to a significantly smaller area of mechanical hypersensitivity, on the morphine-injected side compared with the saline-injected side. These results suggest that morphine can modulate sensitization mechanisms involved in the development of capsaicin-induced mechanical hypersensitivity.
-
Anesthesia and analgesia · Mar 1997
Comment Letter Multicenter Study Clinical TrialThere is no evidence of sevoflurane nephrotoxicity.
-
Anesthesia and analgesia · Mar 1997
Clinical TrialPlasma concentrations of bupivacaine in neonates after continuous epidural infusion.
This study reports plasma bupivacaine concentrations in 13 neonates who received lumbar epidural anesthesia during major abdominal surgery. A bolus of 1.8 mg/kg of bupivacaine (2.5 mg/mL) was administered after induction of anesthesia, followed by a continuous infusion of 0.2 mg.kg-1.h-1 (1.25 mg/mL). Plasma concentrations of total and free bupivacaine and alpha 1-acid-glycoprotein (AAG) were determined. ⋯ However, a substantial number of patients still had increasing concentrations of total plasma bupivacaine at 48 h. Furthermore, the interindividual variation was considerable. These observations cause concern about the safety of epidural infusions longer than 48 h in the age group studied.