Anesthesia and analgesia
-
Anesthesia and analgesia · May 2009
Randomized Controlled Trial Comparative StudyContinuous interscalene brachial plexus block via an ultrasound-guided posterior approach: a randomized, triple-masked, placebo-controlled study.
The posterior approach for placing continuous interscalene catheters has not been studied in a controlled investigation. In this randomized, triple-masked, placebo-controlled study, we tested the hypothesis that an ultrasound-guided continuous posterior interscalene block provides superior postoperative analgesia compared to a single-injection ropivacaine interscalene block after moderately painful shoulder surgery. ⋯ Compared to a single-injection interscalene block, a 2-day continuous posterior interscalene block provides greater pain relief, minimizes supplemental opioid requirements, greatly improves sleep quality, and increases patient satisfaction after moderate-to-severe painful outpatient shoulder surgery.
-
Anesthesia and analgesia · May 2009
Randomized Controlled Trial Comparative StudyDose-dependent suppression of the electrically elicited stapedius reflex by general anesthetics in children undergoing cochlear implant surgery.
Cochlear implants stimulate the auditory nerve to enable hearing. Determining appropriate upper and lower limits of stimulation is essential for successful cochlear implantation. The intraoperative evoked stapedius reflex threshold (ESRT) and evoked compound action potential (ECAP) are commonly used to determine the limits of implant stimulation. In this study, we evaluated the dose-related effects of sevoflurane, desflurane, isoflurane, and propofol on the intraoperative ESRT and ECAP. ⋯ Volatile anesthetics suppress the stapedius reflex in a dose-dependent manner, suggesting that ESRT measurements acquired during volatile anesthesia will overestimate the maximum comfort level, which may cause discomfort postoperatively and adversely affect the child's adaptation to the implant. We advise against the use of volatile anesthetics for measurement of the stapedius reflex threshold during cochlear implant surgery.
-
Anesthesia and analgesia · May 2009
Randomized Controlled Trial Comparative StudySurface anatomy as a guide to vertebral level for thoracic epidural placement.
Precise placement of thoracic epidural catheters is required to optimize postoperative analgesia and minimize adverse effects. Previous research demonstrated that anesthesiologists are inaccurate when using surface anatomy to locate vertebral levels. In this study, we compared the accuracy of two different landmarks to identify the seventh thoracic (T7) spinous process. ⋯ For patients with a BMI <25, the T7 spinous process can be reliably identified to within one interspace in 78% of patients using the C7 (vertebra prominens) surface landmark. Neither the vertebra prominens nor the tip of scapula is a reliable landmark to identify T7 in patients with a BMI >or=25.
-
Amniotic fluid embolism is one of the most catastrophic complications of pregnancy. First described in 1941, the condition is exceedingly rare and the exact pathophysiology is still unknown. The etiology was thought to be embolic in nature, but more recent evidence suggests an immunologic basis. ⋯ Early recognition of amniotic fluid embolism is critical to a successful outcome. However, despite intensive resuscitation, outcomes are frequently poor for both infant and mother. Recently, aggressive and successful management of amniotic fluid embolism with recombinant factor VIIa and a ventricular assist device, inhaled nitric oxide, cardiopulmonary bypass and intraaortic balloon pump with extracorporeal membrane oxygenation have been reported and should be considered in select cases.
-
Anesthesia and analgesia · May 2009
Improving alarm performance in the medical intensive care unit using delays and clinical context.
In an intensive care unit, alarms are used to call attention to a patient, to alert a change in the patient's physiology, or to warn of a failure in a medical device; however, up to 94% of the alarms are false. Our purpose in this study was to identify a means of reducing the number of false alarms. ⋯ Introducing a 19-s alarm delay and automatically detecting suctioning, repositioning, oral care, and washing could reduce the number of ineffective and ignored alarms from 934 to 274. More reliable alarms could elicit more timely response, reduce workload, reduce noise pollution, and potentially improve patient safety.