The Annals of thoracic surgery
-
Two types of ventricular assist systems have been approved for use by the Japanese government. ⋯ From these data, the Toyobo pump and the Zeon pump are useful for short-term support for acute, profound heart failure. The Toyobo pump also may provide sufficient support as a bridge to transplantation for the medium term.
-
New volume requirements for coronary artery bypass grafting are being imposed on cardiac surgeons by hospitals, managed care groups, and others. The rationale for this is unclear. The available literature as well as additional sources relating volume and outcomes in cardiac surgery were extensively reviewed and reexamined. ⋯ Each cardiothoracic surgeon should participate in a national database that permits comparison of his or her outcomes on a risk-adjusted basis with other surgeons. Until conclusive data become available that link volume to outcome, volume should not be used as a criterion for credentialing of cardiac surgeons by hospitals, managed care groups, or others. Instead, each surgeon should be evaluated on his or her individual results.
-
Development of increasingly complex perfusion devices with bonded heparin allowed for significant improvement of thromboresistance of most basic components required for cardiopulmonary bypass. In his recent review of heparin-coated cardiopulmonary bypass circuits, Gravlee cited 91 references dealing with heparin-coated surfaces, and far more can be found if the search includes material technology or heparin-coated devices not designed for cardiopulmonary bypass (eg, ventricular assist devices, hemofilters, catheters). The present review is focused on long-term application of heparin-coated equipment in conjunction with basic work on heparin bonding relevant for extracorporeal membrane oxygenation. ⋯ However, the longest clinical application of a single device is that of an intravascular gas exchanger that remained fully functional during a 29-day implantation period. Finally, it appears, that circulating protamine interacts with surface-bound heparin. Protamine administration should therefore be avoided during perfusion with heparin-bonded equipment to maintain the improved thromboresistance.
-
Blood conservation has become an important issue in cardiac surgery. This study was undertaken to determine if the need of blood transfusion could be predicted from preoperative patient variables. ⋯ These data demonstrate that readily available patient variables can predict patients at risk for transfusion. Routine use of aprotinin and other adjustments of cardiopulmonary bypass should be considered to reduce transfusion in high-risk patients.
-
Right-sided circulatory failure remains a significant source of morbidity and mortality for both cardiac transplant and left ventricular assist device recipients. ⋯ Right ventricular assist devices work most effectively if implanted early enough to avoid significant, potentially irreversible end-organ injury. We liberally employ continuous arteriovenous hemodialysis, minimize the use of heparin immediately postoperatively, keep patients sedated, and continue RVAD support until the patient displays signs of hemodynamic and end-organ recovery as heralded by (1) a decrease in central venous pressure and, more importantly, a decrease in pulmonary artery diastolic pressure, (2) an increase in urine output, and (3) a decrease in serum transaminase levels.