The Journal of hand surgery
-
The distal interosseous membrane (DIOM) of the forearm acts as a secondary stabilizer of the distal radioulnar joint (DRUJ) when the dorsal and palmar radioulnar ligaments of the triangular fibrocartilage complex are cut. Recent anatomical studies revealed that thickness of the DIOM varies widely among specimens and the distal oblique bundle (DOB) exists within the DIOM in 40% of specimens. The DOB originates from the distal one-sixth of the ulnar shaft and runs distally to insert on the inferior rim of the sigmoid notch of the radius. ⋯ Ulnar shortening with the osteotomy performed proximal to the attachment of the DIOM had a more favorable effect on stability of the DRUJ compared with the effect of distal osteotomy, especially in the presence of a DOB. The longitudinal resistance to ulnar shortening was significantly greater in proximal shortening than in distal shortening. It also suggested that the DIOM is of great importance in the management of concomitant ulnar-side injuries in distal radius fracture.
-
Randomized Controlled Trial Comparative Study
Steroid injection versus NSAID injection for trigger finger: a comparative study of early outcomes.
Stenosing tenosynovitis of the flexor tendon sheath of the digits of the hand results from a discrepancy between the diameter of the flexor tendon and its sheath at the A1 pulley. The treatment options for trigger digits include oral nonsteroidal anti-inflammatory drugs (NSAIDs) and local NSAID applications, splintage, steroid injection, and percutaneous and open release of the A1 pulley. Injectable NSAID is used intramuscularly and locally in other sites. The hypothesis is that an injectable NSAID is as effective as the traditionally used steroid injection in the treatment of trigger digit, based on Quinnell grading, and that the treatment works as well in patients with diabetes as in those without diabetes. ⋯ We concluded that, although steroids gave quicker relief, NSAID injections are equally effective at 3 months in the treatment of trigger digits. We were unable to detect a statistically significant difference in the response of patients with and without diabetes to either treatment.
-
Comparative Study
Biomechanical properties of fixed-angle volar distal radius plates under dynamic loading.
To evaluate and compare the biomechanical properties of 8 different locked fixed-angle volar distal radius plates under conditions designed to reflect forces seen in early fracture healing and postoperative rehabilitation. ⋯ This study provides further information to surgeons regarding the relative strengths of different plate options for the treatment of distal radius fractures.