Intensive care medicine
-
Intensive care medicine · Mar 2015
My paper 20 years later: cerebral venous oxygen saturation studied with bilateral samples in the internal jugular veins.
Jugular oxygen saturation monitoring was introduced in neurointensive care after severe traumatic brain injury (TBI) to explore the adequacy of brain perfusion and guide therapeutic interventions. The brain was considered homogeneous, and oxygen saturation was taken as representative of the whole organ. We investigated whether venous outflow from the brain was homogeneous by measuring oxygen saturation simultaneously from the two jugular veins. ⋯ Several groups have confirmed differences between oxygen saturation in the two jugular veins. After years of enthusiasm, interest for jugular saturation has decreased and more modern methods, such as tissue oxygenation monitoring, are now available. Jugular saturation monitoring has low sensitivity, with the risk of missing low saturation, but high specificity; moreover it is cheap, when used with intermittent sampling. Monitoring the adequacy of brain perfusion after severe TBI is essential. However the choice of a specific monitor depends on local resources and expertise.