Intensive care medicine
-
Intensive care medicine · Jan 1992
Comparative StudyMonitoring of central venous oxygen saturation versus mixed venous oxygen saturation in critically ill patients.
Continuous monitoring of mixed venous (SvO2) and central venous (ScO2) oxygen saturation was compared in 7 critically-ill patients (Apache II score: 19 +/- 2.1) to determine whether or not information derived from ScO2 were reliable in clinical practice. Patients were catheterized with both a pulmonary artery (PA) and a central venous (CV) catheter, each of them mounted with fiberoptic sensors (Opticath PA Catheter P7110 and Opticath CV Catheter U440, Abbott). A total of 580 comparative measurements were obtained during periods without and with therapeutic interventions (drug-titration, bronchial suction, use of PEEP, changes in FiO2 ...). ⋯ There were poor correlations between the values during periods without (r = 0.48) and with therapeutic interventions (r = 0.62). Better, but still less than ideal, correlations were obtained with changes in SvO2 and ScO2 during periods without (r = 0.70) and with therapeutic interventions (r = 0.77). Although there is a need to develop a simple technique to monitor mixed venous oxygen saturation, the present study indicates that ScO2 monitoring was not reliable in the study patients.
-
The development of the flexible, fiberoptic bronchoscope has made bronchoscopic examinations possible in ICU patients undergoing mechanical ventilation. Over the years, the number of such procedures has greatly increased, with both diagnostic and therapeutic objectives, such as performing difficult intubation, management of atelectasis and hemoptysis, diagnosis of nosocomial pneumonia in ventilated patients, and early detection of airway lesions in selected situations, such as high-frequency ventilation. The complication rate can be kept low if the endoscopist has a precise knowledge of the many pathophysiological and technical facets particular to bronchoscopy under these difficult conditions. This article reviews some of these aspects, in the light of our personal experience.
-
Intensive care medicine · Jan 1992
A fibre optics system for the evaluation of airway pressure in mechanically ventilated patients.
The present study was intended to evaluate the "in vivo" endotracheal (ET) tube resistance and respiratory mechanics in mechanically ventilated patients with respiratory failure by using fiber optic catheters. ⋯ This study confirms that 48 h after the positioning of ET tubes the airflow resistance is significantly higher than might be expected from the "in vitro" data. The presence of the endotracheal tube can interfere with the evaluation of thoraco-pulmonary mechanics, particularly in dynamic conditions. The fiber optic system represents an interesting and simple tool for the evaluation of ET tube resistance and pulmonary mechanics in patients undergoing mechanical ventilation.
-
Intensive care medicine · Jan 1992
Comparative StudyA comparison of continuous positive pressure ventilation, combined high frequency ventilation and airway pressure release ventilation on experimental lung injury.
In pigs with oleic induced lung injury, the effectiveness of combined high frequency ventilation (CHFV, with VDR-Phasitron) and airway pressure release ventilation (APRV) were compared to continuous positive pressure ventilation (CPPV) in a randomized study. The respiratory rate was 15/min, CPAP 8 mmHg and FiO2 0.25. PaCO2 was maintained at 5 kPa. ⋯ There was no difference in the pericardiac pressure between the 3 ventilation modes. The pressure related depressive effects on the cardiovascular function during CHFV and APRV were similar to those during CPPV. Adequate oxygenation and ventilation could be achieved with both CHFV and APRV, but these methods were not superior to CPPV.
-
Intensive care medicine · Jan 1992
Inspiratory work imposed by continuous positive airway pressure (CPAP) machines: the effect of CPAP level and endotracheal tube size.
Inspiratory work imposed by Continuous Positive Airway Pressure (CPAP) machines has been a matter of concern. The imposed inspiratory work of CPAP machine circuits (Wcir) and the effect of the total breathing apparatus with endotracheal tube (ETT) and connector included in the circuit (Wapp), were measured in three continuous flow (CF) and various configurations of three demand flow (DF) CPAP machines. The performance was assessed at 0, 5, 10 and 15 cmH2O CPAP using a Michigan Instruments Test Lung Model 1600, internal compliance set at 50 ml/cmH2O, driven at square wave inspiratory flows (VI) of 20, 40 and 60 l/min at a tidal volume of 500 ml. ⋯ No consistent advantage of CF over DF machines was demonstrated. There was little advantage of high gas flows (greater than 5 l/min) in various DF circuits. Within an individual machine maximum negative pressures generated during inspiration correlated with both Wcir and Wapp.