Intensive care medicine
-
Intensive care medicine · Jan 1987
Suppression of spontaneous breathing during high-frequency jet ventilation. Separate effects of lung volume and jet frequency.
The effect of ventilatory frequency of high-frequency jet ventilation (HFJV) from 1 to 5 Hz, apart from changes in thoracic volume, on spontaneous breathing activity was studied in Yorkshire piglets under pentobarbital anesthesia. The highest PaCO2 at which the animals did not breathe against the ventilator (apnea point) was established either by changing minute volume of ventilation or by adding CO2 to the respiratory gas. The higher the apnea point, the higher the suppression of spontaneous breathing activity was assumed to be. ⋯ When thoracic volume was kept constant in this way a constant tidal volume at increasing jet frequencies resulted in only a slight increase in suppression of spontaneous breathing. We conclude that the increase in lung volume is a major factor in suppressing central respiratory activity during HFJV. Jet frequency by itself might be an additional suppressive factor.(ABSTRACT TRUNCATED AT 250 WORDS)
-
Intensive care medicine · Jan 1987
Comparative StudyEvaluation of pediatric intensive care in Europe. A collaborative study by the European Club of Pediatric Intensive Care.
There are no reports analyzing the results of pediatric intensive care in Europe. We evaluated quantitatively the severity of illness and the amount of care required for 714 consecutively admitted patients. We used simultaneously the Clinical Classification System (CCS) the Acute Physiology Score (APS) and the Therapeutic Intervention Scoring System (TISS). ⋯ Among these 3 groups the highest mortality was observed in cardio-vascular patients (p less than 0.01 v.s. respiratory, p less than 0.05 v.s. neurologic). The death rate was 22% among the 264 neonates, 9.7% among the 247 infants (p less than 0.01) and 12.6% among the 198 children. APS and TISS scores increased significantly with the CCS classes.(ABSTRACT TRUNCATED AT 250 WORDS)
-
Intensive care medicine · Jan 1987
Case ReportsAirway obstruction associated with an endotracheal tube.
A case of endotracheal tube obstruction with fatal outcome is presented. The obstruction was caused by the endotracheal tube bevel lying against the tracheal wall, the trachea being excessively displaced by the aorta at the level of the aortic knuckle.
-
Intensive care medicine · Jan 1987
Case ReportsBicarbonate haemodialysis: an adequate treatment for lactic acidosis in diabetics treated by metformin.
Lactic acidosis in diabetics on metformin therapy is rare but still associated with poor prognosis. The authors report here five cases. Three patients were initially with a cardiovascular collapse and all had an acute renal failure. ⋯ All patients survived. However, blood metformin levels remained abnormally high at the end of the dialytic therapy. In conclusion, (1) bicarbonate dialysis is an adequate treatment of lactic acidosis observed in diabetic patients treated with metformin since it rapidly corrects the acid-base disorders and partially removes metformin; (2) the sole accumulation of metformin is not sufficient to explain lactic acidosis since this latter might be corrected in spite of persisting high levels of blood metformin.
-
Intensive care medicine · Jan 1987
Case ReportsPost lobectomy atelectasis: the use of a Servo 900 B as a high-frequency ventilator.
High-frequency ventilation (HFV) has been used with good results in a variety of clinical situations where conventional ventilation has proved ineffective. However, all of the reports so far have involved the use of a specially purchased specifically designed ventilator which tends to be unfamiliar to most medical and nursing staff responsible for its use. A case where HFV was used in combination with differential lung ventilation in the treatment of unilateral pulmonary atelectasis is described using a Servo 900B as the high-frequency ventilator. It serves to demonstrate that the Servo 900B can be used as an occasional high-frequency ventilator as required, thus avoiding the expense of purchasing a specialized ventilator.