International orthopaedics
-
The cementless Bicontact total hip arthroplasty (THA) system (AESCULAP AG, Tuttlingen, Germany) was introduced in 1986/1987 and has been in successful clinical use in an unaltered form up to today. Although good long-term results with the Bicontact stem have been published, it is questionable whether the implant provides the criteria for a state-of-the-art stem regarding proximal bone stock preservation. The purpose of the study was to monitor the periprosthetic bone mineral density (BMD) in a prospective two-year follow-up dual-energy X-ray absorptiometry (DEXA) study. ⋯ We conclude that the Bicontact stem provides adequate proximal bone stock preservation. We observed some signs of stress shielding at the tip of the stem, which is inevitable to some degree in THA with cementless straight stems. However, in this prospective DEXA investigation, we showed that proximal off-loading does not occur after THA with the Bicontact system. Thus, we believe that this stem is still a state-of-the-art implant.
-
Conservative treatment of chronic groin pain is prolonged and recurrence is quite common. Coexistence of sports hernia and adductor tendinitis/tendinosis in a single patient is noted in the literature. In our study we evaluated our operative treatment that should enable pain elimination and fast return to sports activities. ⋯ Any surgical procedure used for treating chronic groin pain should address the common causes of pain in this region. Adductor tendinosis can be present in up to 24.2 % of cases with sports hernia or may be isolated in 7 % of cases with chronic groin pain and must be treated by tenotomy. Resection of the genital branch of genitofemoral nerve and ilioinguinal nerve neurolysis should also be performed in patients with sports hernia.
-
To describe the quality of osteosynthesis after intertrochanteric fractures evaluation of tip apex distance (TAD) and position of the hip screw have been established. Furthermore, a slightly valgus fracture reduction has been suggested to reduce the risk of cut-out failure. However, uniform recommendations for optimal screw positioning and fracture reduction are still missing. The purpose of our study was to confirm potential risk factors for cut-out of hip screws of intertrochanteric fractures and to provide recommendations for practical clinical use. ⋯ According to our results, the TAD should not exceed 25 mm in stable (AO/OTA A1) as well as unstable (AO/OTA A2) fractures. An increased anterior hip screw placement should be avoided while fracture reduction with a slight valgus Neck Shaft seems favorable.
-
Traumatic shoulder dislocation may be complicated by concomitant bony injury of the glenoid rim or the humeral head. In Hill-Sachs lesions, reconstruction techniques vary widely and range from open reduction to tendon transposition or humeral head derotation. These operations are extensive and have questionable outcomes. With the expertise from vertebral compression fracture reduction by kyphoplasty, we examined in a cadaver feasibility study whether reduction of the Hill-Sachs lesion via hydraulic lift might be an anatomical and minimally invasive treatment option. We postulated that the use a of a balloon- assisted kyphoplasty reduction could achieve almost anatomical correction of the defect. ⋯ In a preliminary cadaver study we show that using a balloon kyphoplasty system might be an alternative treatment option for Hill-Sachs lesions, with reduced collateral damage that can occur with other minimally invasive techniques. Future work is needed to evaluate the technique under arthroscopic conditions.