Periprosthetic femur fracture is a potentially worrisome phenomenon for cementless stem fixation. The aim of this study was to document the incidence of stem loosening following periprosthetic femur fracture in previously well-fixed cementless grit-blasted tapered-wedge stems. ⋯ Hip arthroplasty using cementless grit-blasted tapered-wedge titanium stems showed higher incidence of stem loosening in association with periprosthetic femur fracture than hip arthroplasty conducted using proximal porous-coated stems. A high index of suspicion of stem loosening might be necessary in periprosthetic femur fracture following hip arthroplasty using this type of stems.
-
The purpose of this study is to report on the cumulative incidence and the outcome of surgically-treated postoperative PPFs in patients with femoral neck fractures treated with a THA or HA using an Exeter stem. ⋯ The cumulative incidence of surgically treated PPFs was considerable among patients with Exeter stems operated due to a femoral neck fracture. The re-operation rate due to fracture-related complications was highest among patients with B2 fractures.
-
The aim of this study was to determine the biomechanical properties of four fixation options for periprosthetic supracondylar femoral fractures. ⋯ The intramedullary fibular strut allograft with polyaxial locking plate did not prove to be significantly better to the polyaxial locking plate only in a periprosthetic distal femur fracture model.
-
The purpose of this study was to test the hypothesis that overstuffing the patellofemoral joint during total knee arthroplasty (TKA) would decrease passive knee flexion and alter patellar kinematics during knee flexion. ⋯ Passive knee flexion after TKA is significantly reduced when overstuffing the patellofemoral joint by +8 mm, and patellofemoral kinematics are altered when overstuffing the joint by +6 mm. These results demonstrate the relatively modest effects of patellofemoral overstuffing on knee flexion and patellar tracking kinematics after TKA.
-
The incidence of periprosthetic fractures is inevitably increasing. Sufficient stabilisation and proper screw placement next to large-volume implants remains difficult. Modern locking plates allow polyaxial, thus bicortical, screw placement around a prosthetic stem. This study analysed the biomechanical properties of different screw configurations in a locking plate construct of a periprosthetic femoral fracture model. ⋯ Bicortical screw placement enhances the primary stability in treating periprosthetic femoral fractures. Notably, the mode of failure may limit the salvage options in case of revision surgery.