The International journal of artificial organs
-
Synchronization between the left ventricle and a left ventricular assist device (LVAD) may be important for ventricular unloading and coronary perfusion. We assessed the synchrony between cardiac and LVAD cycles by increasing delays in steps of 100 msec throughout the cycle, under conditions of total and partial left ventricular support. ⋯ This study shows that the synchronous mode of LVAD operation is feasible. Moreover, a delay in device contraction until the second half of the cardiac cycle optimizes ventricular unloading and may eventually improve myocardial recovery.
-
Continuous veno-venous hemofiltration (CVVH) and mixed acidemia often occur simultaneously in critically ill patients. In a previous study in non-acidemic pigs we found that colloids and CVVH interact specifically with respect to hemodynamic stability, with favorable effects for 6% HES 130/0.4 versus 4% gelatine (GEL) infusion. In a porcine model, we investigated whether these colloid-type associated differences are still dominant under acidemic conditions. ⋯ As in a previous study in non-acidemic pigs, we found a colloid-specific influence of HES130 versus GEL on hemodynamics during CVVH under acidemia. Again, HES130 infusion may lead to favorable effects. In contrast, acidemia without CVVH application was dominant over the impact of a respective colloid. The application of a CVVH seems to be an important trigger for the overall circulatory response to a particular colloid.
-
Comparative Study
Characterizing the impact of minor cannula design modification.
Bench evaluation of the hydrodynamic behavior of venous cannulas is a valuable technique for the analysis of their performance during cardiopulmonary bypass (CPB). The aim of this study was to investigate the effect of the internal diameter of the extracorporeal connecting tube of venous cannulas on flow rate (Q), pressure drop (delta P), and cannula resistance (delta P/Q²) values, using a computer assisted test bench. ⋯ Our results demonstrated that Q was increased but delta P and delta P/Q² values were significantly decreased when the connecting tube diameter was increased for venous cannulas. The connecting tube diameter significantly affected the resistance to liquid flow through the cannula. Smartcanulas® outperform Medtronic cannulas.
-
Cytokines play pivotal roles in the pathophysiology of severe sepsis/septic shock, and continuous hemodiafiltration using a polymethylmethacrylate membrane hemofilter (PMMA-CHDF) removes cytokines efficiently and continuously, mainly through adsorption to a hemofilter membrane. The aim of this study was to investigate the clinical efficacy of enhanced intensity PMMA-CHDF in treating refractory septic shock. ⋯ Enhanced intensity PMMA-CHDF may improve hemodynamics and survival rate in patients with refractory septic shock.
-
Randomized Controlled Trial Comparative Study
Hemodialysis without heparin: a randomized, controlled, crossover study of two dialysis membranes (AN69ST and polysulfone F60).
It has been suggested that clotting of the extracorporeal circuit during hemodialysis (HD) without heparin could be reduced by using the polyacrylonitrile AN69ST membrane. However, this has never been demonstrated in a controlled study. The objective of this study was to compare the AN69ST with a polysulfone membrane during HD without heparin in a controlled study. ⋯ The AN69ST membrane did not decrease the rate of circuit clotting during HD without heparin compared to the polysulfone F60 membrane.