The International journal of artificial organs
-
Hemodialysis access is a challenging problem in patients with exhausted dialysis access sites of their upper extremities. Femoral arterio-venous polytetrafluoroethylene (PTFE) graft is often necessary. The safety and efficacy of cuffed tunneled catheters at the femoral site for long-term hemodialysis has not been extensively studied. ⋯ Our preliminary data suggest that the cuffed tunneled femoral catheter has reasonable access survival and an acceptable risk of infection. It may provide a safe and effective access for long-term hemodialysis patients with exhausted access in their upper extremities, especially high risk patients who are not suitable for femoral PTFE graft creation.
-
Randomized Controlled Trial Clinical Trial
Advanced glycation end products: specific fluorescence changes of pentosidine-like compounds during short daily hemodialysis.
Advanced glycation end products (AGE) accumulate in uremia and represent an important etiopathogenetic cause of morbidity in dialyzed patients. Conventional hemodialysis treatment seems to be ineffective in lowering AGE levels. We wished to investigate whether daily hemodialysis (DHD), a treatment that seems to result in better clinical condition in end-stage renal disease patients, is effective in the reduction of these compounds. ⋯ DHD showed a reduction in AGE-related total fluorescence, although the mean value remained higher than in control subjects. DHD is also accompanied by a decrease in protein-linked pentosidine.
-
It is known that titanium alloys cause more extensive local metallosis due to fretting corrosion than stainless steel implants. The aim of the present study was to investigate possible systemic metal releases (Ti, Al, V, Cr, Ni) in sheep where L4-L5 were implanted with titanium alloy (Ti6Al4V, ASTM F 136) and stainless steel (AISI 316 L). 16 sheep were used: 8 were implanted with Ti6Al4V and 8 with stainless steel. At 6, 12, 24 and 36 months, the following examinations were performed: histology, atomic absorption spectrophotometry (AAS) and scanning electron microscopy (SEM), on liver, lung, kidney, brain, spleen and lumbo-aortic lymph nodes. ⋯ Current data suggest that the amount of Ti found in organs after stable pedicular fixation is extremely low and not biologically available. This observation would lead us to exclude the hypothesis of any toxic reaction and such a release seems to be due to the passive diffusion through lymphatic fluids. Additional studies are needed to confirm if this long-term release of Ti particles might cause tissue damage.
-
In hypothermic cardiopulmonary bypass (CPB), various vasodilators are used to control the perfusion pressure. These agents, however, often decrease the pressure excessively, and the low perfusion pressure may persist until the end of CPB. In this study we evaluate the safety and characteristics of the regulation of perfusion pressure during CPB using a volatile anesthetic, sevoflurane which has an extremely low partition coefficient. ⋯ In all cases, MAP could be maintained adequately. In the sevoflurane group, systemic vascular resistance indices (SVRI) during the rewarming period and at the end of CPB were higher, and doses of norepinephrine needed at the end of CPB were significantly lower than in the chlorpromazine group. The regulation of perfusion pressure during CPB using sevoflurane was safe and could easily maintain adequate SVRI.