Neurosurgery
-
Lumbosacral spondylolisthesis-induced scoliosis is a rare clinical entity. Sagittal reconstruction and the coronal curve evolution after surgery for spondylolisthesis have not been investigated in depth. ⋯ Lumbosacral TLIF can achieve satisfactory slip reduction and scoliosis resolution. Sciatic scoliosis often presents with coronal imbalance but also a preferable curve prognosis. A large Cobb angle and L5 rotation may hinder the resolution of olisthetic scoliosis.
-
The optimal magnetic resonance angiography (MRA) sequence for assessing the aneurysm occlusion state or in-stent flow after endovascular coiling is not well established. ⋯ PETRA-MRA showed excellent diagnostic performance in terms of residual flow detection and in-stent flow assessment. PETRA could be a versatile alternative sequence for following up patients with coiled aneurysm.
-
Subarachnoid hemorrhage (SAH) from an intracranial aneurysmal rupture is the most common nontraumatic etiology for SAH, but up to 15% of patients with SAH have no identifiable source. ⋯ We found a high rate of family history of intracranial aneurysms in patients who presented with naSAH. Although there was no difference in clinical outcome in patients with and without family history, there appears to be a higher percentage of nonperimesencephalic radiographic patterns of SAH in those with family history, suggesting possible different etiologies of these hemorrhages.
-
Embolization of brain arteriovenous malformations (AVMs) using ethylene-vinyl alcohol copolymer (Onyx) embolization may influence the treatment effects of stereotactic radiosurgery (SRS) differently than other embolysates. ⋯ Nidal embolization using Onyx does not appear to differentially impact the outcomes of AVM SRS compared with non-Onyx embolysates. The embolic agent selected for pre-SRS AVM embolization should reflect both the experience of the neurointerventionalist and target of endovascular intervention.
-
Deep brain stimulation (DBS) is a standard of care treatment for multiple neurologic disorders. Although 3-tesla (3T) magnetic resonance imaging (MRI) has become the gold-standard modality for structural and functional imaging, most centers refrain from 3T imaging in patients with DBS devices in place because of safety concerns. 3T MRI could be used not only for structural imaging, but also for functional MRI to study the effects of DBS on neurocircuitry and optimize programming. ⋯ Following careful phantom-based safety testing, 3T structural and functional MRI can be safely performed in subjects with activated deep brain stimulators.