Annals of emergency medicine
-
Randomized Controlled Trial Multicenter Study
Diagnostic Accuracy of Point-of-Care Ultrasound Versus Radiographic Imaging for Pediatric Distal Forearm Fractures: A Randomized Controlled Trial.
In patients aged 5 to 15 years with a clinically nondeformed distal forearm injury presenting to the emergency department (ED), we examined whether point-of-care ultrasound or radiographic imaging had better diagnostic accuracy, with the reference diagnosis determined by an expert panel review. ⋯ In children and adolescents presenting to the ED with a clinically nondeformed distal forearm injury, clinician-performed (acquired and interpreted) point-of-care ultrasound more accurately identified the correct diagnosis than clinician-interpreted radiographic imaging.
-
Randomized Controlled Trial
Atomized Intranasal Ketorolac Versus Intravenous Ketorolac for the Treatment of Severe Renal Colic in the Emergency Department: A Double-Blind, Randomized Controlled Trial.
Atomized intranasal (IN) drug administration offers an alternative to the intravenous (IV) route. We aimed to evaluate the analgesic efficacy of IN versus IV ketorolac in emergency department patients with acute renal colic. ⋯ Neither IN or IV ketorolac was superior to the other for the treatment of acute renal colic, and both provided clinically meaningful reductions in pain scores at 30 to 60 minutes.
-
Acute cholecystitis accounts for up to 9% of hospital admissions for acute abdominal pain, and best practice entails early surgical management. Ultrasound is the standard modality used to confirm diagnosis. Our objective was to perform a systematic review and meta-analysis to determine the diagnostic accuracy of emergency physician-performed point-of-care ultrasound for the diagnosis of acute cholecystitis when compared with a reference standard of final diagnosis (informed by available surgical pathology, discharge diagnosis, and radiology-performed ultrasound). ⋯ Emergency physician-performed point-of-care ultrasound with final diagnosis as the reference standard (7 studies, n=1,772) had a pooled sensitivity of 70.9% (95% confidence interval [CI] 62.3 to 78.2), specificity of 94.4% (95% CI 88.2 to 97.5), positive likelihood ratio of 12.7 (5.8 to 27.5), and negative likelihood ratio of 0.31 (0.23 to 0.41) for the diagnosis of acute cholecystitis. Emergency physician-performed point-of-care ultrasound has high specificity and moderate sensitivity for the diagnosis of acute cholecystitis in patients with clinical suspicion. This review supports the use of emergency physician-performed point-of-care ultrasound to rule in a diagnosis of acute cholecystitis in the emergency department, which may help expedite definitive management.