AJNR. American journal of neuroradiology
-
Mechanical thrombectomy presents today a promising alternative to traditional stroke therapies. Our aim with this study was to evaluate the safety and efficacy of the Catch mechanical thrombectomy device in the treatment of acute stroke and report the angiographic results and clinical outcomes. ⋯ In our retrospective case series, the Catch device appears effective in achieving recanalization and improving 90-day outcome in patients with acute ischemic stroke.
-
AJNR Am J Neuroradiol · Aug 2011
Comparative StudyComparative hospital economics and patient presentation: vertebroplasty and kyphoplasty for the treatment of vertebral compression fracture.
Previous studies evaluating vertebral augmentation procedure costs have not made detailed comparisons between vertebroplasty and kyphoplasty. Our study contrasts hospital costs for vertebroplasty versus kyphoplasty for the treatment of vertebral compression fractures in routine clinical practice in the United States. ⋯ Performing vertebroplasty versus kyphoplasty reduces hospital costs by nearly $5000 for inpatient procedures and by more than $4000 for outpatient procedures.
-
AJNR Am J Neuroradiol · Aug 2011
ReviewStent-assisted coiling in acutely ruptured intracranial aneurysms: a qualitative, systematic review of the literature.
The use of stents for treatment of morphologically unfavorable, acutely ruptured aneurysms is avoided by most operators because of concerns about the risk of using dual antiplatelet therapy in the setting of acute SAH. Our aim was to review the literature regarding stent-assisted coil embolization of acutely ruptured intracranial aneurysms to determine the safety and efficacy of this treatment option. ⋯ Stent-assisted coiling in ruptured aneurysms can be performed with high degrees of technical success, but adverse events appear more common and clinical outcomes are likely worse than those achieved without stent assistance. Thromboembolic complications appear reasonably well-controlled. Reported EVD-related hemorrhagic complications were uncommon, though the total number of EVDs placed was unknown.
-
AJNR Am J Neuroradiol · Aug 2011
Comparative StudyInfluence of hemodynamic factors on rupture of intracranial aneurysms: patient-specific 3D mirror aneurysms model computational fluid dynamics simulation.
Hemodynamics factors play an important role in the rupture of cerebral aneurysms. The purpose of this study was to evaluate the impact of hemodynamic factors on the rupture of the MANs with 3D reconstruction model CFD simulation. ⋯ MANs may be a useful disease model to investigate possible causes linked to ruptured aneurysms. The ruptured aneurysms manifested lower WSS compared with their parent arteries, a higher proportion of the low WSS area to the whole area of aneurysm, and higher OSI compared with the unruptured aneurysms.
-
AJNR Am J Neuroradiol · Aug 2011
Restoration of spinal alignment and disk mechanics following polyetheretherketone wafer kyphoplasty with StaXx FX.
EPFs sustained during VCFs degrade the disk's ability to develop IDP under load. This inability to develop pressure in combination with residual kyphotic deformity increases the risk for adjacent vertebral fractures. We tested the hypothesis that StaXx FX reduces kyphosis and endplate deformity following vertebral compression fracture, restoring disk mechanics. ⋯ StaXx FX reduced endplate deformity and kyphosis, and significantly increased anterior height following VCF. Although height and kyphosis were not fully corrected, the disk's ability to pressurize under load was restored.