Although the prevalence of tuberculosis continues to decline in most developed countries, the risk of healthcare-associated tuberculosis, remains for patients or healthcare staff. Outbreaks of healthcare-associated tuberculosis are usually associated with delays in diagnosis and treatment, or the care of patients in sub-optimal facilities. The control and prevention of tuberculosis in hospitals is best achieved by three approaches, namely administrative (early investigation diagnosis, etc.), engineering (physical facilities e.g. ventilated isolation rooms) and personal respiratory protection (face sealing masks which are filtered). ⋯ Even when policies and facilities are optimal, there is a need to regularly review and audit these as sometimes compliance is less than optimal. The differences in recommendations may reflect the variations in epidemiology and the greater use of BCG vaccination in the UK compared with the United States. There is a strong argument for advising ventilated facilities and personal respiratory protection for the care of all patients with tuberculosis, as multi-drug tuberculosis may not always be apparent on admission, and these measures minimise transmission of all cases of TB to other patients and healthcare staff.
-
The Dutch Working Party on Infection Prevention (WIP) aimed to determine whether certain humidification policies are better than others in terms of prevention of ventilator-associated pneumonia (VAP) in mechanically ventilated intensive care unit (ICU) patients. Publications were retrieved by a systematic search of Medline and the Cochrane Library up to February 2006. All (quasi-) randomized trials and systematic reviews/meta-analyses comparing humidification methods in ventilated ICU patients were selected. ⋯ WIP do not recommend either passive or active humidifiers to prevent VAP, nor the type of passive humidifiers to be used. Regarding active humidification, WIP recommends using heated wire circuits. This is due to the theoretical consideration that less condensate reduces colonization and subsequent risk of spread throughout an ICU when condensate is removed.
-
Initial antibiotic therapy is an important determinant of clinical outcomes in ventilator-associated pneumonia (VAP). Several studies have investigated this issue, with conflicting results. This study investigated risk factors of inadequate empirical antimicrobial therapy and its impact on outcomes for patients with a clinical diagnosis of VAP. ⋯ Multiple logistic regression analysis revealed that the risk of inadequate antimicrobial treatment was more than twice as great for patients with late-onset VAP [odds ratio (OR), 2.93; 95% confidence interval (CI), 1.30-6.64; P=0.01], and more than three times for patients with VAP caused by multidrug-resistant pathogens (OR, 3.07; 95% CI, 1.29-7.30; P=0.01) or with polymicrobial VAP (OR, 3.67; 95% CI, 1.21-11.12; P=0.02). Inadequate antimicrobial treatment was associated with higher mortality for patients with VAP. Two of three independent risk factors for treatment inadequacy were associated with the isolation and identification of micro-organisms.
-
Randomized Controlled Trial
A prospective clinical trial to evaluate the microbial barrier of a needleless connector.
Needleless connectors are being increasingly used for direct access to intravascular catheters. However, the potential for microbial contamination of these devices and subsequent infection risk is still widely debated. In this study the microbial contamination rate associated with three-way stopcock luers with standard caps attached was compared to those with Y-type extension set luers with Clearlink needleless connectors attached. ⋯ The internal surfaces of 20 of 200 (10%) three-way stopcock luers with standard caps were contaminated with micro-organisms whereas only one of 193 (0.5%) luers with Clearlink attached was contaminated (P<0.0001). These results demonstrate that the use of the Clearlink device with a dedicated disinfection regimen reduces the internal microbial contamination rate of CVC luers compared with standard caps. The use of such needle-free devices may therefore reduce the intraluminal risk of catheter-related bloodstream infection and thereby supplement current preventive guidelines.