Recent literature revealed good short-term results after microfracturing (MFX) of isolated focal cartilage defects in the knee joint. Study purpose was a long-term evaluation of patients who received MFX through a multimodal approach, correlating clinical scores and morphological pre- and postoperative MRI-scans. ⋯ Our study demonstrated that MFX as a treatment option for cartilage defect in the knee did not show the anticipated clinical and radiological long-term results. In 12 of 15 patients the cartilage defect size had increased after MFX, in 2 patients indicating full-knee replacement. Especially those with a leg malalignment >5° in varus were more prone to suffer from an increase in defect size. In our cohort the clinical scores correlated with the radiological findings.
-
Quantitative image quality assessment in terms of image noise (IN), contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) in relation to required radiation dose (RD) for dual-energy (DE), standard and low-kVp contrast-enhanced computed-tomography (CT) cholangiography. ⋯ Despite higher IN, low-kilovoltage CT-cholangiography reveals no significant difference with respect to CNR and SNR when compared to linear blended images yielded by DECT. Compared to DECT or conventional CT at 120 kVp, contrast-enhanced low-kVp CT cholangiography potentially allows reduction of patient dose by up to 50% or 20%, respectively. Therefore, CT-cholangiography at 80 kVp should be considered as an alternative to DECT-cholangiography whenever DECT is unavailable, or if increased image quality of DECT regarding quantitative bile duct evaluation is not needed for diagnosis.
-
Comparative Study
Comparison of 3D vs. 2D fast spin echo imaging for evaluation of articular cartilage in the knee on a 3T system scientific research.
We sought to retrospectively compare the accuracy of a three-dimensional fat-suppressed, fast spin-echo sequences acquired in the sagittal plane, with multiplanar reconstructions to that of two-dimensional fat-suppressed, fast spin echo sequences acquired in three planes on a 3T MR system for the evaluation of articular cartilage in the knee. ⋯ There was no significant difference in accuracy for the evaluation of articular cartilage of a single three-dimensional, fast spin echo sequence with multi-planar reformatted images vs. two-dimensional, fast spin echo sequences acquired in all three imaging planes in the knee.
-
To evaluate 5-slice stack/single-slice MRI approaches and anthropometric measures as predictors for metabolically relevant whole-body adipose tissue (AT) compartments in overweight/obese adolescents. ⋯ Anthropometric measures and single-slice MRI can accurately predict TAT/SCAT which cannot be improved by evaluation of 5-slice stacks. Prediction of VAT by 5-slice stack/single-slice MRI protocols seems only to be accurate in females. Anthropometry cannot be reliably used for prediction of VAT in both genders. Thus, MRI seems to be necessary for quantification of VAT in overweight/obese adolescents of both genders.
-
To assess the value of sonographic criteria, based on measurements of joint capsule distension and synovial hyperemia, during the course of repeated ultrasound (US)-guided intra-articular injections of hyaluronic acid (HA) in hand osteoarthritis (OA). ⋯ In this study, we demonstrate the meaningfulness of sonographic evaluation criteria including measurements of joint capsule distension and PDUS vascularization, both significantly correlating with the decrease of pain, during the therapy follow-up of US-guided intra-articular HA-injections in patients with hand OA.